1
2
3
4
5
6
I-6
SM831148
1. Specifications
1-1 Unit Specifications
Wall-Mounted Type
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
Indoor Unit KH2672R
Outdoor Unit C2672R
POWER SOURCE
230 - 208 V / 1 Phase / 60 Hz
PERFORMANCE
Cooling
Capacity * [minimum~muximum] BTU / h 25,200 [9,500~25,200]
(17˚F)** BTU / h
Moisture removal (High) Pints / h 8.1
Air circulation (H / M / L) 230 V CFM 559 / 475 / 390
External Static Pressure
in. WG
S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 14.9
ELECTRICAL RATINGS
Voltage rating V 230 208
Available voltage range V VAC 187 - 253
Max. Running amperes*
A 15.3 16.9
Power input W 2,840 2,840
(17˚F)** W
Back-up Heater kW
Maximum overcurrent protection (Indoor/Outdoor)
A 15 / 30
Low ambient control Built-in 0˚F
Fan speeds Indoor / Outdoor 3 and Automatic control / Variable
Optional Wired Remote Controller
Optional Wireless Remote Controller RCS-SH1UA / RCS-BH80UA. WL
Air deflection (Horizontal / Vertical )
/ Automatic (Vertical )
Air filter Washable
Drain pump (Drain connection)
(20A , OD26mm)
Compressor Rotary(SANYO)
Operation sound
Indoor - Hi/Me/Lo
dB - A 48 / 42 / 38
Outdoor - Hi dB - A 49
Refrigerant control Electronic Expansion Valve (MOV)
REFRIGERANT TUBING
Limit of tubing length ft. (m) 165 (50)
Limit of tubing length at shipment ft. (m) 10~100 (3~30)
Limit of elevation difference ft. (m) Outdoor unit is higher than indoor unit : 100 (30)
between the two units ft. (m) Outdoor unit is lower than indoor unit : 50 (15)
Refrigerant tube Narrow tube in. (mm) 3 / 8 (6.35)
outer diameter Wide tube in. (mm) 5 / 8 (15.88)
Refrigerant amount at shipment lbs. (kg) 4.19 (1.9) - R410A
DIMENSIONS & WEIGHT
Indoor unit Outdoor unit
Unit dimensions Height in. (mm) 12- 63/64 (330) 30- 23/32 (780)
Width in. (mm) 44- 7/8 (1,140) 37 (940)
Depth in. (mm) 8- 31/32 (228) 13- 3/8 (340)
Package dimensions Indoor unit Outdoor unit
Height in. (mm) 15- 11/32 (390) 34- 31/32 (888)
Width in. (mm) 47- 27/32 (1,215) 39- 31/32 (1,015)
Depth in. (mm) 11- 17/32 (293) 16- 3/32 (409)
Net weight lbs. (kg) 40 (18) 128 (58)
Shipping weight lbs. (kg) 44 (20) 148 (67)
Shipping volume cu.ft. (m 3 ) 4.9 (0.139) 13.0 (0.369)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
FEATURES
MODEL No.
Controls Microprocessor
RCS-SH80UG / RCS-TM80BG