Intake coduct
False ceiling
Air intake
Outlet conduct
On the front and rear side of the unit a rectangular port
(with flange) helps during duct mounting. (fig. 2-10)
Rear and front flange for the air intake. The value included
in the brackets is referred to the model X18. (fig. 2-11)
Discarge air duct (optional accessory).
Contact the After Sale Service. (fig. 2-12)
Remove the filter and pour, inside the condensate drain
pan, 0.5 liter of water. Start the unit checking for proper
drain pump operation. (fig. 2-13)
Fig. 2-10
Fig. 2-11
Fig. 2-12
Fig. 2-13
2
1
There is a duct connection port for drawing in fresh air.
The supplementary fan motor for outside air intake has to be supplied separately and controlled by a bipolar ON-OFF switch
with safety fuses.
Fresh air flow must be about 10% of the total air flow to avoid operating problems and noise.
Open the knock-out hole , fix a 120 mm flange on the unit and connect the thermically insulated duct.
Install an outside grille with filter inspection port to prevent dust and leaves from entering and fouling the indoor unit heat
exchanger.
2-1 Duct for fresh air