Sanyo SGP-EW150M2G2W Air Conditioner User Manual


 
14
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
15
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Individual Control Systems Overview
A wide variety of control options to meet the requirements of dierent customers.
Operation system Individual control systems Timer operation
Requirements
Normal
operation
Operation from
each seat
Simple operation
Daily and
weekly programme
External appearance
Type, model name
Timer wired
remote controller
RCS-TM80BG
Wireless remote
controller
RCS-SH80BG.WLB
RCS-TH80BG.WLB
RCS-BH80AG.WLB
RCS-TRP80BG.WLB
RCS-SH1BGB
Simplied remote
controller
RCS-KR1EG
Schedule timer
SHA-TM64AGB
Number of indoor units
which can be controlled
1 group, 8 units 1 group, 8 units 1 group, 8 units
64 groups,
max. 64 units
Use limitations
Up to 2 units can be
connected per group.
Up to 2 units can be
connected per group.
Up to 2 units can be
connected per group.
Power supply from the
system controller.
When there is no system
controller, connection is
possible to the T10 terminal
of an
indoor unit.
Connectable
indoor unit
4 series indoor unit 4 series indoor unit 4 series indoor unit 4 series indoor unit
Function
ON/OFF
-
Mode setting
-
Fan speed setting
-
Temperature setting
-
Air ow direction
-
Permit/Prohibit switching - - - -
Weekly programme
- -
*1 Setting is not possible when a remote control unit is present. (Use the remote control for setting.)
Centralised control systems
Operation with various
function from central
station
Only ON/OFF operation
from central station
Simplied charge ratio for each tenant
Touch screen panel
Personal computer
(eld supply)
External appearance
Type, model name
System controller
SHA-KC64AGB
ON/OFF controller
SHA-KC16KAGB
Intelligent controller
SHA-KT256EG
Communication adaptor
SHA-KA128AGB
Number of indoor units which
can be controlled
64 groups,
max. 64 units
16 groups,
max. 64 units
64 units x 4 systems,
max. 256 units
2 systems,
max. 128 units
Use limitations
Up to 10 units can be
connected to one system.
Main unit/sub unit (1
main unit + 1 sub unit)
connection is possible.
Use without remote
controller is possible.
Up to 8 units (4 main
units + 4 sub units) can be
connected to one system.
Use without remote
controller is impossible.
A communication adaptor
(SHA-KA128AGB) must be
installed for three or more
systems.
Maximum 500 indoor
units (128 per communica-
tion adaptor)
Connectable
indoor unit
4 series indoor unit 4 series indoor unit 4 series indoor unit 4 series indoor unit
Function
ON/OFF
Mode setting
-
Fan speed setting
-
Temperature setting
-
Air ow direction
-
Permit/Prohibit switching
Weekly programme
-
*1 *1
Centralised Control Systems Overview
*1 *1 *1
*1
Web
application