Sanyo SGP-EW150M2G2W Air Conditioner User Manual


 
10
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
11
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
System configured at site
Main
Hot Water
Boiler
Hot water inlet: Rø3/4
Hot water outlet: Rø3/4
Hot Water
Storage
Tank
Water piping
GHP
OUT
IN
GU Type Heat Exchanger & CFR Units
SANYO’s new heat recovery ventilation system allows
total control via a system network whilst modulating the
temperature and humidity of incoming air supply.
• Integration of heat recovery ventilation and DX coil technology
for optimum air temperature control
• Connects to all ECO & GHP outdoor units with a lter option
• 3 Way: Solenoid valve kit is required for each unit
• 2 Way: RAP kit is required for each unit
Indoor unit specications
Model Name SPW-GU055XH SPW-GU075XH SPW-GU105XH
Air circulation (H) m³/h 500 750 1,000
Power source 220/230/240V, 1 phase - 50 Hz
Fresh air load
treatment capacity
UK Cooling kW 5.3 (1.7)*¹ 8.2 (2.6)*¹ 10.7 (3.4)*¹
UK Heating kW 6.5 (2.3)*¹ 9.8 (3.5)*¹ 12.6 (4.6)*¹
Enthalpy exchange
eciency
UK Cooling % 59
UK Heating % 67
Temp exchange eciency 75
Equivalent cooling capacity
kW 3.6 5.6 7.3
BTU/h 12,000 19,000 25,000
Power input
Cooling kW 0.532 0.737 0.798
Heating kW 0.532 0.737 0.798
Running current
Cooling Amps 2.4 3.2 3.5
Heating Amps 2.4 3.2 3.5
Fan motor
Type Sirocco fan
External static pressure-return air Pa 183 (170) 221 (188) 135 (88)
External static pressure-supply air Pa 205 (182) 264 (218) 176 (137)
Output kW 0.28 (4P)x2 0.35 (4P)x2
Sound pressure level (C/H) db(A) 46 (Cooling), 47 (Heating) 47 (Cooling), 48 (Heating) 48 (Cooling), 49 (Heating)
Dimensions
Height mm 425 450
Width mm 1785 1903
Depth mm 1000 1120 1220
Piping connections
Liquid (are) mm (inches) 6.35 (1/4)
Gas (are) mm (inches) 12.7 (1/2)
Drain piping VP-25
Connection duct diameter mm 250 300
Net weight kg 134 153 168
The values in ( ) for the external static pressure and operating sound are for use of booster cable. *1: Heat recovery capacity by heat exchanger. Data subject to change without notice.
The CFR- PHE uses a unique purifying Bioxigen system to
produce negative ions this can reduce pollutants by up to
85% whilst improving, signicantly air quality within most
environments.
• High eciency heat exchanger & Easy to clean lters
The CFR-PHE unit structure is constructed from Aluzink frame
work and galvanised steel with 20 mm thick re resistant
acoustic insulation, reducing both weight and sound levels to
a minimum. The system is supplied with ducted spigots which
can be positioned either at the front or side of the unit to ease
installation.
Indoor unit specications
Model CFR/ CFR-PHE 33 55 110 175 220
Nominal air ow * m3/hr 300 620 920 1580 1850
External Static Pressure pa 45 55 65 70 77
Sound Pressure ** dB(A) 43 51 50 53 52
Fans
Power in Watts 184 340 294 700 700
Absorbed power A 0.75 1.8 2.2 4.4 4.8
Fan speeds no 1 3
Insulation Class F
Electrical supply v/ph/htz 230/1/50
Bioxigen Elements (PHE only)
Number of elements 2 X C 2 X F
Electrical supply v/ph/htz 230/1/50
Power in Watts 8 8 8 8 8
Filter EU3
Paper Heat Exchanger CFR-PHE
Temperature Eciency heating *** 76% 74% 72% 68% 73%
Temperature Eciency cooling **** 62% 60% 58% 54% 59%
* Nominal air ow ** Sound pressure 1.5 mts from the unit in free eld *** Data referred to -5
0
C 80% RH OAT room condition 20
0
C 50% RH **** Data referred to 32
0
C 50% RH OAT room condition 26
0
C 50% RH
The high eciency low pressure loss total heat exchanger
is made of specially treated paper to enable the unit to be
as ecient as 76% during normal operation. This allows
system to recover both latent and sensible heat.
Additional GHP Functions
GHP Chiller available with outdoor unit capacities from 71kW
Water Heat Exchanger
Air Handling Unit
Water Piping
Duct
Outdoor unit
Operating condition Cooling
Heating
(standard)
Heating
(low temperature)
Water temperature of water heat exchanger unit
Outlet 7°C
Outlet 45°C Outlet 45°C
Outdoor side intake air temperature 35°C DB 7°C DB, 6°C WB 2°C DB, 1°C WB
Note: The gas consumption can be 110% of the specication value depending on the
operating conditions.
The SANYO ECO G Water Heat Exchanger can provide
water at a wide range of temperatures suitable for a
variety of commercial applications ranging from comfort
air conditioning to food processing or the replacement of
boilers and other systems.
• New 25 kW and 50 kW capacity models
• In cooling (chiller) mode provides water from -15°C to 15°C
• In heating mode can provide hot water up to 55°C, for example
for under oor heating applications
• Includes water ow protection to prevent freezing
• Temperature sensor included
• S-Link communication is connectable with any controllers
• Split system means reduced installation cost and the use of a
less powerful circulation pump
One touch changeover between cooling and heating operation
• The system can accommodate up to 120m (actual length) of
piping between the outdoor unit and the water heat exchanger,
allowing exibility of installation location
• The system uses antifreeze coolant, so it can produce cold water
even at -15°C, thereby complying with “brine specications”
Model No. SGP-WE80M1 SGP-WE170M1
SGP-EW120M2G2W
Cooling capacity kW 25 30
Heating capacity kW 30 35.5
SGP-EW150M2G2W
Cooling capacity kW 25 37.5
Heating capacity kW 30 45
SGP-EW190M2G2W and
SGP-EGW190M2G2W
Cooling capacity kW 25 50
Heating capacity kW 30 60
SGP-EW240M2G2W
Cooling capacity kW 25 56
Heating capacity kW 30 67
Electrical rating
Cooling power input
kW 0.01
Heating power input
kW 0.01
Power supply 220/230/240V Single Phase 50Hz
Size
Height mm 1,000
Width mm 550
Depth mm 965
Weight kg 125 160
Standard cold/hot water ow rate m
3
/h 4.3 8.6
Hydrostatic loss kPa 8.5 11.3
Holding water quantity inside the unit m
3
0.01 0.02
Minimum holding water quantity outside the unit
m
3
0.28 0.50
Piping refrigerant
Gas pipe mm ø22.22 ø28.58
Liquid pipe mm ø9.52 ø15.88
Heat exchanger hot/cold heat exchanger
Water circuit limit pressure MPa 0.686
Anti-freezing protection system Protective thermostat
Specications subject to change without notice.
Hot water supply function (during cooling or heating operation)
SGP-EW120M2G2W SGP-EW150M2G2W SGP-EW190M2G2W SGP-EW240M2G2W SGP-EGW190M2G2W
The engine waste heat, which is normally exhausted into
the atmosphere, is recovered via the heat exchanger and
eectively used as hot water, so the GHP system acts as a
subsystem that alleviates the load on the client’s main hot
water system and therefore oers “free” hot water.
Water heating capacity up to 65 kW (of 75°C hot water)
Hot water piping allowable pressure 0.7 MPa
Hot water circulation rate 2 - 3.9m
3
/h
Hot water pipe size 3/4 inch