Sanyo SAP-K77RAX Air Conditioner User Manual


 
Control PCB
Control Circuit Fuse
Controls
Part No.
Microprocessor
250V 3.15A
CR-K127GAX
1 ... D102 / L637
RCS-7S2E-G
Cross-Flow
DC 12V
Each Pair of Terminal : 200 +/- 7%
Stepping Motor
24BYJ48-916
Aluminum Plate Fin / Copper Tube
2
1.1
0.162
Fan
Remote Control Unit
Q'ty ... Dia. and Length
Type
mm
Coil Resistance
Rating
Model
Flap Motor
Type
(Ambient Temp. 25 °C)
Ohm
Face Area
Coil
Rows
Fin Pitch
Heat Exchanger Coil
m
2
mm
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Indoor Unit SAP-K127RAX
-
AC Motor
IBH-884-066B ... 1
4
BRN-WHT : 234
PNK (RED)-WHT : 209
12.5
1,300
Thermal fuse
130
1.5
450
Fan Motor
Coil Resistance
Rough Measure RPM (Cool)
Type
Model ... Q'ty
No. of Poles
Safety Device
Type
Operating Temp.
Close
Open °C
(Ambient Temp. 20 °C)
Micro F
VAC
W
Ohm
Nominal Output
Run Capacitor (on controller PCB)
11