Sanyo KMH0922 Air Conditioner User Manual


 
10
WM700700
7. ELECTRICAL DATA
Electrical Characteristics
CMH1822 / KMH0922 (×1)
Remarks: Rating conditions are:
Cooling: Outside air temperature 95°F DB/75°F WB
Indoor unit entering air temperature 80°F DB/67°F WB
Heating: Outside air temperature 47°F DB/43°F WB
Indoor unit entering air temperature 70°F WB
Performance at
Indoor Unit Outdoor Unit Complete Unit
230/208V – 1ø – 60Hz
Fan Motor Max. Heat Fan Motor Compressor Heat-pump Max. Heat
Cooling
Rating
A 0.15 / 0.14 0.52 / 0.52 3.43 / 3.64 4.1 / 4.3
Conditions
W 34 / 29 116 / 104 750 / 737 900 / 870
Heating
Rating
A 0.15 / 0.14 4.35 / 3.93 0.52 / 0.52 3.43 / 3.64 4.1 / 4.3 8.45 / 8.23
Conditions
W 34 / 29 1,000 / 818 116 / 104 750 / 737 900 / 870
Locked-Rotor Amperes A 0.19 / 0.18 0.71 / 0.64 27
Remarks: Rating conditions are:
Cooling: Outside air temperature 95°F DB/75°F WB
Indoor unit entering air temperature 80°F DB/67°F WB
Heating: Outside air temperature 47°F DB/43°F WB
Indoor unit entering air temperature 70°F WB
Performance at
Indoor Unit Outdoor Unit Complete Unit
230/208V – 1ø – 60Hz
Fan Motor Max. Heat Fan Motor Compressor Heat-pump Max. Heat
Cooling
Rating
A 0.30 / 0.28 0.52 / 0.52 7.38 / 7.90 8.2 / 8.7
Conditions
W 68 / 58 116 / 104 1,636 / 1,618 1,820 / 1,780
Heating
Rating
A 0.30 / 0.28 8.70 / 7.86 0.52 / 0.52 6.68 / 7.10 7.5 / 7.9 16.2 / 15.76
Conditions
W 68 / 58 2,000 / 1,636 116 / 104 1,456 / 1,428 1,640 / 1,590 3,640 / 3,226
Locked-Rotor Amperes A
0.19 × 2 / 0.18 × 2
0.71 / 0.64 27 × 2—
CMH1822 / KMH0922 (×2)