Sanyo KMH0922 Air Conditioner User Manual


 
6
WM700700
208V
CMH1822 / KMH0922 (×1)
TC: Total Cooling Capacity (BTU/H)
SHC: Sensible Heat Capacity (BTU/H)
kW: Compressor Input (kW)
Remarks: Rating conditions (* mark) are: Outside ambient temperature 95°F DB
Indoor unit entering air temperature 80°F DB/67°F WB
Rating Capacity: 8,700 BTU/H Air Flow Rate: 210 CFM
Evaporator Condenser
Ent. Temp. °F/(°C) Ambient Temp. °F/(°C)
WB DB
75 85 95 105 115
(23.9) (29.4) (35.0) (40.6) (46.1)
TC 8,610 8,220 7,830 7,390 6,790
kW 0.61 0.66 0.72 0.78 0.86
59 72 (22.2) SHC 6,090 5,880 5,680 5,450 5,150
(15.0) 76 (24.4) SHC 6,800 6,590 6,390 6,160 5,860
80 (26.7) SHC 7,550 7,340 7,130 6,910 6,610
84 (28.9) SHC 8,260 8,050 7,830 7,390 6,790
88 (31.1) SHC 8,610 8,220 7,830 7,390 6,790
TC 8,910 8,630 8,290 7,840 7,220
kW 0.61 0.67 0.73 0.80 0.88
63 72 (22.2) SHC 5,180 5,040 4,870 4,660 4,370
(17.2) 76 (24.4) SHC 5,890 5,750 5,590 5,370 5,090
80 (26.7) SHC 6,630 6,500 6,330 6,120 5,830
84 (28.9) SHC 7,350 7,210 7,050 6,830 6,550
88 (31.1) SHC 8,060 7,930 7,760 7,550 7,220
TC 9,150 9,000 *8,700 8,220 7,660
kW 0.62 0.68 0.74 0.81 0.90
67 72 (22.2) SHC 4,230 4,160 4,030 3,820 3,580
(19.4) 76 (24.4) SHC 4,940 4,870 4,740 4,530 4,290
80 (26.7) SHC 5,690 5,620 5,490 5,280 5,040
84 (28.9) SHC 6,400 6,330 6,200 5,990 5,750
88 (31.1) SHC 7,110 7,050 6,910 6,700 6,460
TC 9,440 9,280 9,050 8,640 8,130
kW 0.62 0.68 0.75 0.83 0.91
71 72 (22.2) SHC 3,250 3,190 3,100 2,940 2,740
(21.7) 76 (24.4) SHC 3,970 3,900 3,810 3,650 3,450
80 (26.7) SHC 4,710 4,650 4,560 4,400 4,200
84 (28.9) SHC 5,430 5,360 5,270 5,110 4,910
88 (31.1) SHC 6,140 6,080 5,980 5,820 5,630
TC 9,620 9,520 9,310 8,980 8,610
kW 0.64 0.70 0.76 0.85 0.94
75 76 (24.4) SHC 3,000 2,960 2,880 2,760 2,640
(23.9) 80 (26.7) SHC 3,740 3,700 3,630 3,510 3,380
84 (28.9) SHC 4,450 4,420 4,340 4,220 4,090
88 (31.1) SHC 5,170 5,130 5,050 4,940 4,810