Sanyo KHS2432 Air Conditioner User Manual


 
Operation with the Remote Control Unit (continued)
NOTE
Choose the best position in the room for the remote control unit, which
also acts as the sensor for room comfort and transmits the operating
instructions. Once you’ve found this best position, always keep the
remote control unit there.
This appliance has a built-in 3-minute time delay circuit to ensure
reliable operation. When the operation button is pressed, the
compressor will start running within three minutes. In the event of
power failure, the unit will stop. When the power is restored, the unit
will restart automatically after three minutes.
3. Adjusting the
Fan Speed
A. Automatic Simply set the FAN SPEED selector button to the position.
A microcomputer in the air conditioner controls the fan speed automatically
when the
mode is selected. When the air conditioner starts operating,
the difference between the room temperature and the set temperature is
detected by the microcomputer which then automatically switches the fan
speed to a suitable level.
Cooling mode:
When difference between
room temperature and set
temperature is
FAN SPEED
4 °F and over High
Between 4 °F and 2 °F Medium
Below 2 °F Low
Heating mode:
When difference between
room temperature and set
temperature is
FAN SPEED
4 °F and over High
Below 4 °F Medium
NOTE
The above table assumes that the sensor in the remote control is being
used. If the sensor in the indoor unit is being used (the
indicator is on),
actual operation may differ slightly from the operation described in the
table.
(Referto‘SENSORbuttononpage10.)
B. Manual If you want to adjust fan speed manually during operation, just set the FAN
SPEED selector button as desired by following STEP 4 on page 14. [
,
,or ]
15OI-212-15EG
oi212001