Sanyo C1852 Air Conditioner User Manual


 
– 35 –
SM830079
11. SERVICE PROCEDURES
3) Outdoor Unit does not Run.
A. Check COOL / FAN selector switch in the remote control unit.
B. Check set temperature.
0623_X_S
• Is COOL/FAN selector switch
set to COOL ?
NO
Set to COOL.
0624_X_S
Try to lower set
temperature by Temperature
setting button “COOLER”.
• Set “Operation selector”
switch to TEST in the
indoor unit.
YES
Outdoor unit runs.
Is room temperature too
low ?
NO
• Try to run both indoor and
outdoor units with another
remote control unit.
OK
The other remote control
unit is defective.
(Room sensor in the remote