Samsung UM27A1C3 Air Conditioner User Manual


 
A
B
Deciding on Where to Install the Air Conditioner(cont.)
160 mm
(6 inch)
or more
25 mm (1 inch)
or more
Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.
18,000Btu/h
Piping length and the height.
100 mm
(4 inch)
or more
100 mm
(4 inch)
minimum
600 mm
(24 inch)
minimum
600 mm (24 inch)
minimum
100 mm
(4 inch)
minimum
A-unit
9,000 Btu/h
B-unit
9,000 Btu/h
Circuit breaker
(20A)
Main power switch
P
REPARING THE
INSTALLATION
B
(3 metres/9ft 10in maximum)
A
(15 metres/49ft 3in
maximum)
AM18A1C09 UM18A1C2 1,208-230~,60
Indoor unit Outdoor unit
Power supply
Ø, V, Hz
A-unit
B-unit
Pipe size
Unit
Liquid
1/4
"
1/4
"
GAS
3/8
"
3/8
"
MAX.
piping length
A
15 m (49ft 3in)
15 m (49ft 3in)
MAX.
height
B
3 m (9ft 10in)
3 m (9ft 10in)
A
B
INDOOR UNIT
OUTDOOR UNIT
E-
27