Samsung NH200WHXES Heat Pump User Manual


 
Operating advanced function _33
ENGLISH
Remote Controller Setting Range : Code 10✴✴
Space Cooling
Target water outlet temperature : Upper limit(#1011, Default 25ºC, Range : 18 ~ 25ºC),
Lower limit(#1012, Default 16ºC, Range : 5 ~ 18ºC)
- With this default FSV settings, user can change the target water outlet temperature within
the range of 5 ~ 25ºC for cooling
Target room temperature : Upper limit(#1021, Default 30ºC, Range : 24 ~ 30ºC),
Lower limit(#1022, Default 18ºC, Range : 18 ~ 22ºC)
- With this default FSV settings, user can change the target room temperature within the
range of 18 ~ 30ºC for cooling.
• The #1 DIP switch in the wired remote controller should be set to “OFF”(Default) for
cooling operation of heat pump.
• The #2 DIP switch in the wired remote controller should be set to “OFF”(Default) to
control the water outlet temperature.
• The #2 DIP switch in the wired remote controller should be set to “ON” to control the
room temperature.
• The #3 DIP switch in the wired remote controller should be set to “OFF”(Default) to
control the air sensor in remote controller.
• The #3 DIP switch in the wired remote controller should be set to “ON” to control the
external air sensor.
Space Heating
Target water outlet temperature : Upper limit(#1031, Default 55ºC, Range : 37 ~ 55ºC),
Lower limit(#1032, Default 25ºC, Range : 15 ~ 37ºC)
- With this default FSV settings, user can change the target water outlet temperature within
the range of 25 ~ 55ºC for heating.
Target room temperature : Upper limit(#1041, Default 30ºC, Range : 24 ~ 30ºC),
Lower limit(#1042, Default 16ºC, Range : 16 ~ 22ºC)
- With this default FSV settings, user can change the target room temperature within the
range of 16 ~ 30ºC for heating.
• The #2 DIP switch in the wired remote controller should be set to “OFF”(Default) to
control the water outlet temperature.
• The #2 DIP switch in the wired remote controller should be set to “ON” to control the
room temperature.
Field Setting Value
Main Menu &
Code
Sub Menu Function Description
Sub
Code
Default Min Max Step Unit
Remote
Controller
Setting Range
Code 10✴✴
Water Out Temp for Cooling
Max ✴✴11 25 18 25 1 ˚C
Min ✴✴12 16 5 18 1 ˚C
Room Temp for Cooling
Max ✴✴21 30 24 30 1 ˚C
Min ✴✴22 18 18 22 1 ˚C
Water Out Temp for Heating
Max ✴✴31 55 37 55 1 ˚C
Min ✴✴32 25 15 37 1 ˚C
Room Temp for heating
Max ✴✴41 30 24 30 1 ˚C
Min ✴✴42 16 16 22 1 ˚C
DHW Tank Temp
Max ✴✴51 50 50 70 1 ˚C
Min ✴✴52 40 30 40 1 ˚C
DHW Heating
Target DHW tank temperature : Upper limit(#1051, Default 50ºC, Range : 50 ~ 80ºC),
Lower limit(#1052, Default 40ºC, Range : 30 ~ 40ºC)
- With this default FSV settings, user can change the target tank temperature within the
range of 40 ~ 50ºC for DHW heating.
The FSV #3011 in the wired remote controller should be set to “1(Yes)” to use DHW
function.