Drain Hose
Connecting the pipe
Drilling a Hole in the Wall
Drill a hole of 60mm(2
")
in diameter to the outside.
The drilling should be done at a distance of less than
150mm(5
")
from the floor facing the indoor unit.
Extend the drain hose to the drain hose connected to
the drain pan, and fix it with the tape or a cable tie to
prevent separation. Then make a covering of it so
that water cannot flow outwardly.
The piping of this unit can be connected to the right, left, or
rear side. When you hit the area for piping connection slightly
with a hammer, a hole is made.
CAUTION
1. As the draining is of natural drain type, make the drain hose direct
downward.
2. If there is any foreign substance in the drain plate, it may clog the
drain pipe. Therefore, be sure to remove the foreign substance
inside after installation.
3. After completion of installation, be sure to pour water into the drain
pan, and then check the draining condition.
(There is no problem in draining when the draining is completed
within 20 seconds.)
Less than
150mm
(5 )
8
7"
60mm
(2 )
8
3"
Foamed Polyethylene
Insulator
Vinyl Chloride(Inner diameter ø 18mm
"
)
Outer diameter ø 23mm
"
)
Piping Material
Holes for piping
connection (3 points)