Samsung AD26B1C13 Air Conditioner User Manual


 
17
3-3-7 If Operation By Remote Control Unit Is Impossible. (Initial Diagnosis)
1) Troubleshooting procedure
Remove power cord and plug in again approx. 5 Seconds
Is operation lamp blinking?
Check as in the procedure “NO Power parts”.
Refer to page 11.
Normal
Replace battery.
LCD is faulty.
Replace button.
Micom is faulty.
Receiver module is faulty.
Q601(C4375Y) or Q602(C1623Y) is faulty.
IR LED(CL-1L5EU) is faulty.
“ “ sound heard from the indoor unit when ON/OFF
button on the remote control unit pushed?
Voltage of battery less than 2.5V (Remote Control Unit)?
LCD display status of REMOCON normal?
Voltage at PIN #30 of Remocon Micom change?
Voltage at collecter of Q601 or Q602 change?
Voltage at pin #26 of micom (IC04) change (INDOOR UNIT)?
Micom (IC04) is faulty.
Transmission display lamp ( ) blinking when
ON/OFF button on the remote control unit pushed?
NO
YES
YES
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
NO
NO
YES
DB98_05645A(1)_1 5/30/02 7:04 PM Page 17