Robertshaw Deluxe Programmable Thermostats Thermostat User Manual


 
INSTALLER SETTINGS (continued)
AUXILIARY HEAT
The 9920i can be set to use your 2H/2C heat pump internal auxiliary heating or to use an exter-
nal add-on source. The add-on feature will be used most often when a single stage heat pump
uses a gas or electric furnace as its second stage of heating.
RESIDUAL COOL
In order to get greater efficiency from the cooling system, the fan can be programmed to run for
0 (OFF), 30, 60, 90, or 120 seconds after the air conditioner has shut off.
BALANCE POINTS
This screen will appear only when the optional outdoor sensor 9025i is connected to the
thermostat. When this sensor is used with the 9920i, you can set the lower temperature (below
which the heat pump will not run) and upper temperature (above which the 2
nd
stage heat will not
run). This promotes efficient operation of the heating system.
AUTO CHANGEOVER
When turned on, the thermostat will switch automatically between heating and cooling to maintain
the optimal temperature in your home.
22
INSTALL MENU
SELECT
AUTO CHANGEOVER
DISABLE
ENABLE
INSTALL MENU
SELECT
AUXILIARY HEAT
STANDARD - COMP. =ON
ADD ON - COMP. =OFF
INSTALL MENU
SELECT
RESIDUAL COOL
SECONDS DELAY
60
INSTALL MENU
SELECT
BALANCE POINTS
LOW BALANCE 45 ˚F
HIGH BALANCE 95 ˚F
110-1069B.qxd 3/4/05 3:51 PM Page 22