Robertshaw 9710 Thermostat User Manual


 
The Robertshaw Model 9710 is compatible with 24V AC multi-stage gas, oil, or electric heating/cooling
systems with up to 3 stage heat/2 stage cool. It will operate with multi-stage heating/cooling systems that are
automatic or manual changeover.
This thermostat will automatically control the heating and/or air conditioning system. Once programmed, it
will automatically adjust the temperature setting and fan operation at your programmed times. When used
properly, this thermostat can reduce heating and cooling costs throughout the year.
TABLE OF CONTENTS
Product Features....................................2
KeyPad Quick Reference ......................3
Important Safety Information ..............5
Helpful Programming Tips....................6
NiteView™ LCD Display Backlight ......8
Removing Thermostat from Wiring
Subbase ................................................9
Programming ......................................11
Set or Change Time, Day, etc............11
Selecting ˚F/˚C....................................13
Program Overview ............................13
Programming with Quickset ............15
Review, Change, or Personalize ......17
Review or Modify Program ..............20
Energy Efficient Recovery (EER™) ..21
4
Programming Filter Monitor ............22
Checking Filter Monitor ....................22
Resetting Filter Monitor ....................22
Programming Keypad Lock ..............23
Unlocking Keypad ............................24
Operation ............................................25
Beginning Programmed
Operation. ..........................................25
Resetting Thermostat ........................26
Compressor Protection ....................26
Selecting Auto Changeover..............27
24V AC Circuit Power Monitor..........29
LED Indicator ....................................29
Changing Dip Switch Settings..........30
Replacing The Back-Up Batteries......31
Cleaning and Repair..............................33
Troubleshooting ....................................34
Warranty ................................................39
37
Symptom Remedy
System will not enter AUTO Thermostat must be in PROGRAM mode to run AUTO system operation.
(Auto Changeover) mode. Press PROG/MAN button until PROGRAM is indicated in display. Then,
press SYSTEM button until AUTO is indicated in display.
Room temperature reading is If you have attached remote sensors, the thermostat will display the
inaccurate. average temperature of the activated sensors. See "INSTALLATION
INSTRUCTIONS" and "CHANGING DIP SWITCH SETTINGS".
If there are no remote sensors attached, make sure that the remote sensor
dip switch settings on the rear of the thermostat body are turned off and
the MAIN thermostat dip switch is turned on. See "CHANGING DIP
SWITCH SETTINGS."
Thermostat will not let me change AUTO (changeover) mode may be active. See OPERATION - Selecting
setpoint temperature above or below Changeover). AUTO will be indicated in display.
a certain point.
Thermostat turns on system before my Energy Efficient Recovery (EER™) is in effect. This optional feature turns
programmed setpoint time. on the system prior to the next setpoint time to reach the temperature you
have programmed. See "PROGRAMMING" and “ENERGY EFFICIENT RECOVERY.”
"CHECK FILTER" is indicated in main display. See "PROGRAMMING - Programming Filter Monitor".