SECTION 11: USER INSTRUCTIONS
19
11.4.2 To Turn the Heater Off
Set the installed remote controls to the "OFF"
position.
The burner will turn off immediately.
The fan will continue to run for a few minutes.
To restart, turn the control used above to "ON".
11.5 Simple Fault Finding
Some possible reasons for the heater not operating
are:
1. Gas supply not turned "ON".
2. Electricity supply not turned "ON".
3. The time and/or temperature controls are not
"ON".
4. The limit thermostat may have operated. This
may be caused by an interruption of the electri-
cal supply or failure of the distribution fan.
If the limit thermostat persistently operates, there is
a fault which must be investigated by a contractor
qualified in the installation and service of gas-fired
heating equipment.
11.5.1 Simple Fault Finding (Burner Faults)
If the burner fails to ignite for any reason, it will go to
lockout. This will be indicated by the red light on the
back of the heater or at the remote indicator (if
fitted).
1. Press in and release the lockout reset button. If
a remote reset is not fitted, a reset button is on
the back of the heater.
See Page 5, Section 4.1.
Lockout should not occur during normal operation of
the heater and indicates there is a fault condition
which must be corrected.
WARNING
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. DO NOT try to light any appliance.
3. DO NOT use electrical switches.
4. DO NOT use any telephone in
your building.
5. Leave the building.
6. Immediately call your local gas
supplier after leaving the building.
Follow the gas suppliers
instructions.
7. If you cannot reach your gas
supplier, call the Fire Department.
Fire Hazard
Do not store or use petrol or other
flammable vapours and liquids in the
vicinity of this or any other appliance.
Some objects will catch fire or explode
when placed close to heater.
Failure to follow these instructions can
result in death, injury or property
damage.