Roberts Gorden CRV-B-12A Gas Heater User Manual


 
CRV-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL
52
14.5 Maintenance Checklist
Installation Code and Annual Inspections:
All installations and service of ROBERTS GORDON
®
products must be performed by a contractor qualified
in the installation and service of products sold and
supplied by Roberts-Gordon and conform to all
requirements set forth in the ROBERTS GORDON
®
manuals and all applicable governmental authorities
pertaining to the installation, service and operation of
the equipment. To help facilitate optimum
performance and safety, Roberts-Gordon
recommends that a qualified contractor annually
inspect your ROBERTS GORDON
®
products and
perform service where necessary, using only
ROBERTS GORDON
®
replacement parts.
WARNING
Explosion Hazard
Service and annual inspection must be done by a
contractor qualified in the installation and service of
gas-fired heating equipment or your gas supplier.
Turn off gas and electrical supplies before performing
service or maintenance.
Failure to follow these instructions can result in death,
injury or property damage.
The Vicinity of the Heater Do not store or use flammable objects, liquids or vapors near the heating sys-
tem. Immediately remove these items if they are present.
See Page 3, Section 3.
Vehicles and Other
Objects
Maintain the clearances to combustibles.
Do not hang anything from, or place anything on, the heater.
Make sure nothing is lodged underneath the reflector, in between the tubes or
in the decorative or protective grilles (included with select models).
Immediately remove objects in violation of the clearances to combustibles.
See Page 3, Section 3.
Reflector Make sure there is no dirt, sagging, cracking or distortion.
Do not operate if there is sagging, cracking or distortion.
Make sure reflectors are correctly overlapped. See Page 19, Figure 7.4.3.
Clean outside surface with a damp cloth.
Vent Pipe Venting must be intact. Using a flashlight, look for obstructions, cracks on the
pipe or gaps in the sealed areas or corrosion.
The area must be free of dirt and dust.
Remove any carbon deposits or scale using a wire brush.
Outside Air Inlet Inlet must be intact. Look for obstructions, cracks on the pipe or gaps in the
sealed areas or corrosion.
The area must be free of dirt and dust. Clean and reinstall as required.