Roberts Gorden CRV-B-10 Gas Heater User Manual


 
CRV-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL
36
FIGURE 18: EP-300 Series Horizontal Venting Configurations
10' (3 m) Maximum and 1 Elbow
Approved
Thimble
Vent Terminal
Tjernlund VH1-
6" (15 cm)
or Equivalent
(Not Included)
6" (15 cm)
Bird Screen
(Included)
18" (46 cm) Minimum -
40" (102 cm) Maximum
10' (3 m) Maximum and 1 Elbow
6" (15 cm)
Band Clamp
Single Wall Pipe/Tube 6" (15 cm)
Pitch single wall pipe
downward away from
pump 1/4" ( 6 mm) for
every 10' (3 m).
Part Number Description Part Number Description
01330203 Tee, 4" (10 cm) Aluminized 91409403 Tube, Aluminized 4" (10 cm) dia. 10' (3 m)
01330204 Tee, 6" (15 cm) Aluminized 91409420 Tube, Aluminized 6" (15 cm) dia. 10' (3 m)
01331900 Damper Coupling, 4" (10 cm) 91412800 Flexible Boot, 4" (10 cm)
01335801 Elbow, 4" (10 cm) Aluminized 90° 91412802 Flexible Boot, 6" (15 cm)
01397400 Bird Screen, 6" (15 cm) 91418200 Tube Adapter, 6" (15.2 cm) dia. x 4" (10 cm) dia.
02537801-1P Vent Terminal (Non-Combustible Wall) 91901300 Boot Clamp, 4" (10 cm)
02718851 Drain Cap, 4" (10 cm) 91913703 Boot Clamp, 6" (15 cm)
02718852 Drain Cap, 6" (15 cm) E0009356 Damper Coupling, 6" (15 cm)
90502100 Vent Terminal, 4" (10 cm) (Combustible Wall) T0100320 Elbow, 6" (15 cm) Aluminized 90°
90502101 Vent Terminal, 6" (15 cm) (Combustible Wall)
90502302 Vent Cap, 6" (15 cm) Metalbestos
90505600 Wall Thimble, 4" (10 cm)