Roberts Gorden 30 - 125 Electric Heater User Manual


 
Dimension Data -
Standard UHA Range (Models 150 - 400)
Model 150 175 200 225 250 300 350 400
'A' Width [in] 43 43 43 43 43 50 50 50
'B' Height [in] 27 27 35.25 35.25 35.25 43.5 43.5 43.5
'C' Depth [in] 30 30 32 32 32 30 30 30
'D' Support Spacing [in] 17.6 17.6 17.6 17.6 17.6 24.7 24.7 24.7
'F' Center of Flue [in] 9.5 9.5 17 17 17 13.6 13.6 13.6
'G' Flue Center to Air Intake Center [in]
6 6 6 6 6 7 7 7
'H' Position of Flue [in] 4.5 4.5 4.75 4.75 4.75 4.9 4.9 4.9
'J' Gas Inlet Position [in] 5.9 5.9 5.9 5.9 5.9 8.7 8.7 8.7
'K' Electrical Supply Position [in] 3.4 3.4 3.4 3.4 3.4 6.2 6.2 6.2
Maximum Recommended
Mounting Height to Heater Base [ft]
20 20 25 25 25 30 30 30
Clearances to Combustibles - Standard UHA Range (Models 150 - 400)
Above Heater
6"
Below Heater
3"
To Side of Heater
6"
To Rear of Heater
24" Airow Clearance
To Front of Heater
118"
Access Side Door
31" Access Clearance
To Flue
2"





















Combat
®
UHA 150 - UHA 400 Clearance and Dimension Data