Dimension Data -
Low-Prole UHA Range (Models 30 - 125)
Model 30 45 60 75 100 125
'A' Height [in] 12 12 17.75 17.75 23 23
'C' Center of Flue [Top Option] [in] 5.2 5.2 5.2 5.2 6.9 6.9
'D' Center of Flue [in] 2.5 2.5 2.5 2.5 2.5 2.5
Recommended Mounting
Height to Heater Base [ft]
10 10 12 12 20 20
Clearances to Combustibles - Low Prole UHA Range (Models 30 - 125)
Above Heater
1"
Below Heater
0"
To Side of Heater
1"
To Rear of Heater
18" Airow Clearance
To Front of Heater
118"
Access Side Door
18" Access Clearance
To Flue
2"





























Combat
®