ritetemp 8035C Thermostat User Manual


 
RESET
MENU
PROG
RESET
MENU
PROG
7 Wire Connections cont
When you have finished connecting
the wires, close cover and attach
control unit to wall unit. Hook the top
of the body onto the base, swing the body down, and
snap the body onto the base.
If you do not find the wiring information for your
system try our website at 
www.ritetemp-thermostats.com 
or Customer Support at
888-515-2585
8 Check Unit
Follow these procedures to verify you have
correctly installed the unit.
To check HEAT mode:
ï Set the mode switch to HEAT. Set the fan switch AUTO.
ï Touch the main temperature display then touch the TEMP UP arrow to
raise the target temp to 90
o
. Touch HOME. Wait 5 min.
ï Verify that heat is blowing from the system.
To check COOL mode:
ï Set the mode switch to COOL.
ï Touch the main temperature display then touch the
TEMP DOWN arrow to 5
o
below the room
temperature. 
ï Touch HOME. Wait 5 min.
ï Verify that cool air is blowing from the system.
To check Fan: (If you connected the G wire)
ï Switch Mode to OFF during fan test.
ï Switch the FAN switch to the ON position. Verify
air is blowing from vents. 
ï After test, return to Fan switch to AUTO, and
Mode to HEAT or COOL
Congratulations, you have successfully installed your unit. Please
proceed to the OPERATING Guide to initialize the new thermostat.
REMEMBER, Mode Switch must be in HEAT or COOL to operate.
PG 9
PG 10
Mode
Switch
Fan
Switch
MENU
button
PROGRAM
button
B
G
Y
R
C
From heat pump
w/o Aux heat
O
or
Go To Page 15