PG 8
PG 7
Please refer back to these guidelines for safe and secure wire connections.
ï
Take care not to damage the labels for each wire in handling.
ï
Strip insulation 3/8 in. (9.5mm) from wire ends.
ï
Connect labeled wires only to a terminal with corresponding letter.
ï
Bend the wire slightly, insert the wire under the screw and tighten the
down onto the wire.
Before you Connect Wires
Caution
Do not allow
wires to touch
each other or parts on unit.
Wires must be routed through
the hole in the back plate, below
the terminal block, or they will
hit parts on the cover.
Make sure your wires are labeled . This is necessary to determine which step-by-step
wiring diagram you should use. This may require you to find the 'other end' connection for
each wire on your heating or air conditioning equipment and read the label there.
If you have a Zoned Heating/Cooling system with multiple the rmostats, please refer to our
website at www.ritetemp-thermostats.com for installation not es or call 1-888-515-2585.
7 Wire Connections
What Wires Do You Have?
RH
G
Y
W
C
From Furnace
And AC unit
R
or
RC
G
Y
W
C
From Furnace
And AC unit
RH
Go To Page 13
Go To Page 14
W
RH
R
or
From Furnace
Go To Page 11
C
Go To Page 12
R
or
RH
W
C
From Furnace
G