ritetemp 401-014 Thermostat User Manual


 
PG 14
PG 13
From Furnace
and AC unit
G
W
Y
RH
RC
C
R
G
Y
W
C
RH
or
From Furnace
and AC unit
STEP 1 - Connect the Y wire to the
Y terminal on the thermostat. This
connects to the Cooler compressor.
STEP 2 - Connect the RH or R wire
to the RH terminal on the thermostat.
This connects the Heater/Cooler
Power.
STEP 3 - Connect the W wire to the W terminal on the
thermostat. This connects to the heater control line.
STEP 4 - Connect the G wire to the G terminal on the
Thermostat. This connects to the Fan.
Your HVAC system is now connected to the thermostat.
STEP 1 - Remove the red Jumper
wire.
STEP 2 - Connect the Y wire to
the Y terminal on the thermostat.
This connects to the Cooler
compressor.
STEP 3 - Connect the RH wire to the RH
terminal on the thermostat. This connects to the
Heater Power .
STEP 4 - Connect the RC wire to the RC terminal on
the thermostat. This connects to the Cooling Power .
STEP 5 - Connect the W wire to the W terminal on the thermostat.
This connects to the heater control line.
STEP 6 - Connect the G wire to the G terminal on the Thermostat.
This connects to the Fan.
Your HVAC system is now connected to the thermostat.
Return To Page 7
Return To Page 7
5 WIRE
4 WIRE
NOTE: Wires marked with the dotted line are optional.
NOTE: Wires marked with the dotted line are optional.
HVAC SYSTEM
jumper
wire
Heat
Power
Heat
W
G
RH
C
FAN
Y
Cool
Comp
Thermostat
HVAC SYSTEM
Remove
jumper
wire
HEAT
Power
Heat
W
G
RHRC
C
FAN
Y
Cool
Comp
COOL
Power
Thermostat
A
A