Rinnai RHFE-431FA Furnace User Manual


 
FEATURES OF THE RHFE-431FA UNITS
SAFETY DEVICES
– 1 –
Clean Heating Forced Flue Type
Easy Operation One-Touch Ignition
Sensible Temperature Control Feature
Comfortable Room Temperature Control and Display
Warm Air Outlet at Floor Level (Keeps Your Feet Warm)
Child Safety Lock
Room Temperature Setting Memory
Dirty Air Filter Indicator Lamp
Energy-Saving Economy Setting
Humidifier Tray
Air Flow Directional Louvers
Direct Vent Easily Installed
Proportional Heating Variable Capacity
Hush! Quiet Operation
Modern Design Minimizes Floor Space Requirements
Failure Message Display
Spark Safety Device: Automatically shuts unit down when there is an abnormal spark at time
of ignition. Display lamps LOW, 60, and 64 will activate if this
happens.
Flame Failure Device: Activated when burner flame fails, indicator lamp ON flashes. If
burner fails to ignite, indicator lamp 60 flashes. This prevents raw
gas from being released.
Overheat Switch: This device automatically cuts the gas off if the heater exceeds a
predetermined temperature. This is normally caused by an
obstruction in front of the louvers, or a blocked fan filter. Indicator
lamp 68 ON and the FILTER indicator lamp flash when overheat
switch is activated.
Two Fusible Links: Backs up the overheat switch. If the fusible link cuts the unit off, a
service call by an authorized person is required to replace the link.
Indicator lamps 68 , FILTER and ON will flash.