Rinnai EX22C (RHFE-559FTA) Furnace User Manual


 
Rinnai Corporation EX17C / EX22C Manual 13
Fault Codes
If there is a malfunction the appliance may shut down
as a safety precaution and display a fault code to
assist in diagnosing the problem. The fault code will
flash in the display on the control panel. When
making a service call, this code will assist with
diagnosing the fault.
You may be able to clear the fault code by turning the
heater off and then on again. If the fault code remains
or returns on the next operation, contact Rinnai or
your nearest service agent and arrange for a service
call.
[1]Only this code is dim.
[2]If the fusible link needs replacement, it must be done by a qualified service agency. In addition, the cause of
the overheat needs to be determined. The fusible link is a one use safety device that breaks to shut off the
appliance.
[3]Remove any obstructions. The flue needs to be kept clear to expel exhaust gases. If the appliance fails to
operate contact a qualified service agency.
CODE DISPLAYED FAULT REMEDY
11 [1] Ignition Failure
Check that gas is turned ON.
Check that the vent termination is not blocked.
Refer to the Restart Function explanation.
Service call if repeated.
14 Overheat
Clean filter.
Service call if repeated. [2]
16 Room Overheat Ensure that room temperature is less than 104°F (40°C).
31
Room Temperature Sensor
Faulty
Service call.
32
33
Overheat Temperature
Sensor Faulty
Service call.
34
49 Sensor Breakdown Service call.
53 Sparker Failure Service call.
61 Combustion Fan Failure Service call.
70
Faulty ON/OFF Switch or
Faulty “Set back” Switch
Service call.
71 Faulty Solenoids Service call.
72 Faulty Flame Rod Service call.
73 Communication Error Service call.
99 Flue Block Check around the flue terminal for blockage. [3]
62 Convection Fan Failure Service call.