Rheem Indirect Water Heater Water Heater User Manual


 
Page 3
G
Cold Inlet,
3/4" NPT
Hot Outlet/
Anode Rod,
3/4" NPT
Anode
Rod
Aquastat
T&P Relief
Va lve
From Boiler
Supply, 1" NPT
To Boiler
Return, 1"
NPT
Drain
Va lve
F
D
C
E
B
A
SECTION I: SPECIFICATIONS
Foam insulation standard on indirect water heater models. Pressures, all: Test pressure, 300 PSI Working pressure, 150 PSI
Standard voltage, all: 120V, 60Hz, 1P. T&P valve installed; nipples supplied for top connection.
WARNING: Installation should be in accordance with all national and/or local codes.
CAUTION: The recommended water temperature setting for normal residential use is 120°F. Rheem recommends a tempering valve or anti-scald valve be
installed and used according to the manufacturer's directions to prevent scalding.
STID30
22´´
35
1
/4´´ 27
3
/4´´ 19
1
/2´´ 11
3
/4´´ 6
1
/2´´ 4
1
/2´´
n/a
STID40 22´´
42
1
/4´´ 34
3
/4´´ 31
1
/2´´ 16
3
/4´´ 6
1
/2´´ 4
1
/2´´
n/a
STID50 22´´
48
1
/4´´ 39
3
/4´´ 31
1
/2´´ 16
3
/4´´ 6
1
/2´´ 4
1
/2´´
n/a
STID80
24´´
64´´ 57
1
/8´´
33´´
19
1
/4´´
8´´ 5´´ 5´´
STID120
28´´
65´´ 57
3
/4´´ 33
3
/4´´ 16
1
/4´´ 8
3
/4´´
5´´
6
1
/2´´
Model
A
B
C
D
E
F
G
H
Table 1: Dimensions
G
H
A
E
F
D
C
B
Cold Inlet,
1" NPT
Hot Outlet,
1 1/2" NPT
Anode
Rod
Anode
Rod
T&P Relief
Va lve
From Boiler
Supply, 1" NPT
To Boiler
Return,
1"NPT
Drain
Va lve
Aquastat
Figure 2: STID80, STID120
Dimensions
Figure 1: STID30, STID40, STID50