Rheem AP13731 Water Heater User Manual


 
16
Installing the water heater:
Additional Considerations
Do Not install vent terminal under any patio or deck.
To help prevent moisture from freezing on walls and under
eaves, do not locate vent terminal on the side of a building
with prevailing winter winds.
To help prevent water lines from freezing do not locate vent
terminal on the side of a building with prevailing winter
winds.
Do Not terminate vent directly on brick or masonry surfaces.
A rust-resistant sheet metal backing plate
(2 x 2 feet) (60 x 60 cm) is recommended behind vent. (See
illustration.)
Do Not locate vent terminal too close to shrubbery, as flue
gasses may damage them.
Caulk all cracks, seams and joints within six (6) feet (1.8 m)
of vent terminal.
Caulk around thimble face plate for weather tight seal.
All painted surfaces should be primed to lessen the chance of
physical damage. Painted surfaces will require maintenance.
Insulate vent pipe of indoor water heaters exposed to cold
conditions (attics, crawl spaces, etc.) with inflammable
material to help prevent moisture from accumulating in vent
pipe.
Do Not extend exposed vent pipe of indoor water heaters
outside of building.
Guard vent against accidental contact with people and pets.
(1.8 m)
If soffit vent is too close,
block off and install new
vent at another location
Inside
corner
Caulk
Caulk
Caulk
6' (1.8 m)
caulk zone or
to edge of
window etc., starting
within 6' (1.8 m)
Rising moisture will collect under eaves
4'
6' (1.8 m) caulk
zone
6'
(1.2 m)
WARNING: Moisture in the flue gas will condense as it
leaves the vent terminal. In cold weather this condensate can
freeze on the exterior wall, under the eaves and on
surrounding objects. Some discoloration to the exterior of
the building is to be expected. However, improper location
or installation can result in severe damage to the structure
or exterior finish of the building
Outdoor Water Heater
Indoor Water Heater
Inside
Corner
Caulk
6’(1.8 m)
Caulk Zone
If soffit vent is too close,
block off and install new
vent at another location.
Caulk
Caulk
Rising moisture will
collect under eaves.
6’
4’
2 ft. sq. (60 x 60 cm) sheet metal plate on
brick or masonary surface, recommended.
(1.8 m)
6’(1.8 m)
Caulk
zone or to edge of window
etc.,starting within 6’(1.8 m).
RTV silicone caulk
(1.2 m)