Regency
®
U39 ULTIMATE Direct Vent Freestanding Gas Stove
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The ULTIMATE Direct Vent Freestanding Gas
Stove must be installed in accordance with these
instructions. Carefully read all the instructions in
this manual fi rst. Consult the building authority
having jurisdiction to determine the need for a
permit prior to starting the installation.
Note: Failure to follow the instructions
could cause a malfunction of the
heater which could result in death,
serious bodily injury, and/or property
damage. Failure to follow these
instructions may also void your fi re
insurance and/or warranty.
Note: These instructions take preced-
ence over Simpson Dura-Vent
instructions.
SPECIFICATIONS
Fuels: U39-NG1 is approved for use with
natural gas.
U39-LP1 is approved for use with
liquefi ed petroleum gases (propane).
Electrical: 120V A.C. system.
Circulation Fan: Variable speed, 125/75.
Log Sets: Ceramic fi bre, 7 per set.
Vent System: Coaxial (6-5/8" outer / 4" inner
liner) rigid fl ue and termination cap.
INFORMATION FOR
MOBILE/
MANUFACTURED
HOMES AFTER
FIRST SALE
This Regency
®
product has been tested and
listed by Warnock Hersey as a Direct Vent
Wall Furnace to the following standards: CAN/
CGA-2.17-M91 and ANSI Z21.88b-2003/CSA
2.33b-2003.
This Direct Vent System Appliance must be
installed in accordance with the manufacturer's
installation instructions and the Manufactured
Home Construction and Safety Standard, Title
24 CFR, Part 3280, or the current Standard of
Fire Safety Criteria for Manufactured Home
Installations, Sites, and Communities ANSI/
NFPA 501A, and with CAN/CSA Z240-MH
Mobile Home Standard in Canada.
INSTALLATION
This appliance installation must comply with
the manufacturer's installation instructions and
local codes, if any. In the absence of local codes
follow the current National Fuel Gas Code, ANSI
Z223.1 and the current National Electrical Code
ANSI/NFPA 70 in the U.S.A., and the current
CAN/CGA B149 Gas Installation Code and the
current Canadian Electrical Code CSA C22.1
in Canada.
This Regency
®
Mobile/Manufactured
Home Listed appliance comes factory
equipped with a means to secure the
unit.
AWAY FROM FURNITURE AND
DRAPERIES.
WARNING: FAILURE TO INSTALL
THIS APPLIANCE CORRECTLY
WILL VOID YOUR WARRANTY
AND MAY CAUSE A SERIOUS
HOUSE FIRE.
CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE
HAZARDS OF HIGH SURFACE
TEMPERATURES, ESPECIALLY
THE FIREPLACE GLASS,
AND SHOULD STAY AWAY TO
AVOID BURNS OR CLOTHING
IGNITION.
YOUNG CHILDREN SHOULD
BE CAREFULLY SUPERVISED
WHEN THEY ARE IN THE SAME
ROOM AS THE APPLIANCE.
CLOTHING OR OTHER
FLAMMABLE MATERIAL SHOULD
NOT BE PLACED ON OR NEAR
THE APPLIANCE.
1) Provide adequate clearances for
servicing, proper operation and around
the air openings into the combustion
chamber.
2) The appliance may be installed on a fl at,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or it can
be raised up on a platform to enhance
its visual impact. The appliance may be
installed on carpeting, tile, wood fl ooring
or other combustible material, because the
appliance's metal pedestal base extends the
full width and depth of the appliance. The
ULTIMATE Direct Vent Freestanding Gas
Stove can be installed in a wide variety of
ways and will fi t nearly any room layout.
It may be installed in a recessed position,
framed out into the room, or across a
corner.
3) The ULTIMATE Direct Vent Freestanding Gas
Stove is approved for alcove installations,
which meet the clearances as listed in the
"Locating Your Ultimate Gas Stove" section.
This unit is approved for manufactured
home installations, see "Rigid Pipe Venting
Arrangements" section for the required
vent arrangements. If installed into a
manufactured home the unit must be bolted
down to the fl oor.
This Regency
®
Mobile/Manufactured
Home listed appliance comes equipped
with a dedicated #8 ground lug to which
an 18 gauge copper wire from the steel
chassis ground must be attached.
This appliance may only be installed
in an aftermarket permanently located,
manufactured (mobile) home, where
not prohibited by local codes.
This appliance is only use with the type
of gas indicated on the rating plate.
This appliance is not convertible for
use with other gases, unless a certifi ed
kit is used.
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of
the following:
INSTALLATION AND REPAIRS
SHOULD BE DONE BY A
QUALIFIED SERVICE PERSON.
THIS APPLIANCE SHOULD
BE INSTALLED, REPAIRED,
INSPECTED BEFORE USE AND
AT LEAST ANNUALLY BY A
QUALIFIED SERVICE PERSON.
MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE
LINT FROM CARPETING, ETC.
IT IS IMPERATIVE THAT THE
CONTROL COMPARTMENT,
BURNERS AND CIRCULATING
AIR PASSAGEWAYS OF THE
APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES,
THE APPLIANCE SHOULD BE
LOCATED OUT OF TRAFFIC AND