OPERATING INSTRUCTIONS
8) Rotate the HEAT control to adjust the flame
height higher or lower.
SHUTDOWN
INSTRUCTIONS
1) Use the Burner ON/OFF switch, thermo-
stat or remote control to turn off the burner.
2) Push in the PILOT knob slightly and turn
clockwise to off. Do not force.
3) Turn off all electric power to the appliance
if service is to be performed.
FIRST FIRE
The FIRST FIRE in your stove is part of the paint
curing process. To ensure that the paint is
properly cured, it is recommended that you
burn your fireplace for at least four (4) hours
the first time you use it with the fan on. When
first operated, the unit will release an odour
caused by the curing of the paint and the
burning off of any oils remaining from manu-
facturing. Smoke detectors in the house may
go off at this time. Open a few windows to
ventilate the room for a couple of hours. The
glass may require cleaning.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS STILL HOT!
Note: When the glass is cold and the
appliance is lit, it may cause con-
densation and fog the glass. This
condensation is normal and will
disappear in a few minutes as the
glass heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
OPERATING
INSTRUCTIONS
Before operating this appliance, proceed
through the following check list.
1) Read and understand these Instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the three pieces of door glass
are properly positioned. Never operate the
appliance with any of the glass removed or
with the door open.
5) Verify that all venting and the cap is unob-
structed.
6) Verify log placement. If the pilot cannot be
seen when lighting the unit - the logs or the
embers have been incorrectly positioned.
7) The unit should never to turned off and on
without a minimum of a 60 second wait.
IMPORTANT: The PILOT knob cannot be
turned from pilot to off unless it is partial-
ly depressed.
Note: Open the pedestal door of the unit
before lighting the pilot. Once the
pilot is lit, close the door. You
should never operate the unit with
the door open.
1) If the PILOT knob is in the off position
proceed to Step 4.
2) Push in PILOT knob slightly and turn clock-
wise to off. Knob cannot be turned from
pilot to off unless knob is pushed in slight-
ly. Do not force.
3) Wait five minutes to allow gas, that may
have accumulated in the main burner com-
partment, to escape. If you smell gas, follow
the instructions on the front of this manual.
If you don't smell gas continue on to the next
step.
4) Turn the PILOT knob counterclockwise to
pilot and align it with the arrow as shown
in diagram above.
5) Push in PILOT knob all the way in and hold.
Immediately push IGNITOR button until pilot
lights. Continue to hold the PILOT knob in for
approximately one minute, then release the
PILOT knob. The pilot flame should continue
to burn. If the pilot does not remain lit, repeat
operation allowing a longer period before
releasing PILOT knob.
6) Turn PILOT knob counter clockwise to on.
7) Use the Burner ON/OFF switch to turn on
the burner.
During the first few fires, a white film
may develop on the glass front as part
of the curing process. The glass
should be cleaned or the film will bake
on and become very difficult to re-
move. Use a non-abrasive cleaner and
NEVER clean the glass while it is hot.
FINAL CHECK
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
1) Clocking the appliance to ensure the cor-
rect firing rate (rate noted on label) at 15
minutes.
2) If required, adjusting the primary air to
ensure that the flame does not carbon. First
allow the unit to burn for 15 min. to stabilize.
3) Check for proper draft.
CAUTION
Any alteration to the product that causes
sooting or carboning that results in dam-
age to the exterior facia is not the respon-
sibility of the manufacturer.
CAUTION
Do not connect the millivolt
remote control wires to
the 120V wires.
3) Install 3 AAA alkaline batteries in transmit-
ter and 4 AA alkaline batteries in the
receiver. Install the receiver and its cover
in the wall. Switch the remote receiver to
"remote" mode. The remote control is now
ready for operation.
LIGHTING
INSTRUCTIONS
IMPORTANT
To ignite or reignite the pilot,
the door to the firebox must
be opened.
Only when the pilot holds, without pressure
being applied to the control knob, should the
door to the firebox be closed. The unit must
never be operated with the glass or door
open.