Regency U39-LP Stove User Manual


 
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove
5
IMPORTANT:
SAVE THESE
INSTRUCTIONS
The ULTIMATE Direct Vent Freestanding Gas
Stove must be installed in accordance with
these instructions. Carefully read all the in-
structions in this manual first. Consult the
building authority having jurisdiction to deter-
mine the need for a permit prior to starting the
installation.
Note: Failure to follow the instructions
could cause a malfunction of the
heater which could result in death,
serious bodily injury, and/or prop-
erty damage. Failure to follow
these instructions may also void
your fire insurance and/or war-
ranty.
Note: These instructions take prece-
dence over Simpson Dura-Vent
instructions.
SPECIFICATIONS
Fuels:U39-NG is approved for use with nat-
ural gas.
U39-LP is approved for use with lique-
fied petroleum gases (propane).
Electrical: 120V A.C. system.
Circulation Fan: Variable speed, 125/75.
Log Sets: Ceramic fibre, 7 per set.
Vent System: Coaxial (6-5/8" outer / 4" inner
liner) rigid flue and termination cap.
INFORMATION FOR
MOBILE/
MANUFACTURED
HOMES AFTER
FIRST SALE
This Regency product has been tested and
listed by Warnock Hersey as a Direct Vent Wall
Furnace to the following standards: CAN/CGA-
2.17-M91 and ANSI Z21.88b-2003/CSA 2.33b-
2003.
This Direct Vent System Appliance must be
installed in accordance with the manufactur-
er's installation instructions and the Manufac-
tured Home Construction and Safety Standard,
Title 24 CFR, Part 3280, or the current Standard
of Fire Safety Criteria for Manufactured Home
INSTALLATION
Installations, Sites, and Communities ANSI/ NFPA
501A, and with CAN/CSA Z240-MH Mobile
Home Standard in Canada.
This appliance installation must comply with the
manufacturer's installation instructions and local
codes, if any. In the absence of local codes
follow the current National Fuel Gas Code,
ANSI Z223.1 and the current National Electrical
Code ANSI/NFPA 70 in the U.S.A., and the
current CAN/CGA B149 Gas Installation Code
and the current Canadian Electrical Code CSA
C22.1 in Canada.
AND CIRCULATING AIR PASSAGE-
WAYS OF THE APPLIANCE BE
KEPT CLEAN.
DUE TO HIGH TEMPERATURES,
THE APPLIANCE SHOULD BE LO-
CATED OUT OF TRAFFIC AND
AWAY FROM FURNITURE AND
DRAPERIES.
WARNING: FAILURE TO INSTALL
THIS APPLIANCE CORRECTLY
WILL VOID YOUR WARRANTY AND
MAY CAUSE A SERIOUS HOUSE
FIRE.
CHILDREN AND ADULTS SHOULD
BE ALERTED TO THE HAZARDS
OF HIGH SURFACE TEMPERA-
TURES, ESPECIALLY THE FIRE-
PLACE GLASS, AND SHOULD
STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.
CLOTHING OR OTHER FLAMMA-
BLE MATERIAL SHOULD NOT BE
PLACED ON OR NEAR THE APPLI-
ANCE.
1) Provide adequate clearances for servic-
ing, proper operation and around the air
openings into the combustion chamber.
2) The appliance may be installed on a flat,
solid, continuous surface (e.g. wood, met-
al, concrete). This may be the floor, or it can
be raised up on a platform to enhance its
visual impact. The appliance may be in-
stalled on carpeting, tile, wood flooring or
other combustible material, because the
appliance's metal pedestal base extends
the full width and depth of the appliance.
The ULTIMATE Direct Vent Freestanding
Gas Stove can be installed in a wide variety
of ways and will fit nearly any room layout.
It may be installed in a recessed position,
framed out into the room, or across a
corner.
3) The ULTIMATE Direct Vent Freestanding
Gas Stove is approved for alcove installa-
tions, which meet the clearances listed on
page 7. This unit is approved for manufac-
tured home installations, see page 11 for
the required vent arrangements. If installed
This Regency Mobile/Manufactured
Home Listed appliance comes factory
equipped with a means to secure the
unit.
This Regency Mobile/Manufactured
Home listed appliance comes
equipped with a dedicated #8 ground
lug to which an 18 gauge copper wire
from the steel chassis ground must be
attached.
This appliance may only be in-
stalled in an aftermarket perma-
nently located, manufactured (mo-
bile) home, where not prohibited
by local codes.
This appliance is only use with the
type of gas indicated on the rating
plate. This appliance is not con-
vertible for use with other gases,
unless a certified kit is used.
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of the
following:
INSTALLATION AND REPAIRS
SHOULD BE DONE BY A QUALI-
FIED SERVICE PERSON. THIS AP-
PLIANCE SHOULD BE INSTALLED,
REPAIRED, INSPECTED BEFORE
USE AND AT LEAST ANNUALLY BY
A QUALIFIED SERVICE PERSON.
MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE
LINT FROM CARPETING, ETC. IT
IS IMPERATIVE THAT THE CON-
TROL COMPARTMENT, BURNERS