Regency U32S-LP5 Indoor Fireplace User Manual


 
25U32S-5 FPI Direct Vent Gas Insert
FAN MAINTENANCE
If your fan requires maintenance or replacement, access to the fan is
through the plate on the rear wall of the rebox. NOTE: the unit MUST
NOT be operated without the fan access panel securely in place.
Caution: Label all wires prior to disconnecting when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
MAINTENANCE
1) Turn the unit off and allow it to cool down to room temperature.
2) Disconnect the power source and turn off the gas supply to the
insert.
3) Open the bottom louver.
4) Remove the door frame by lifting out from the bottom and lift up off
the glass door.
5) Remove the glass door.
a) Remove the 2 hooks shown below at the bottom of the glass
door
.
b) Swing the door out 45
o
from the bottom and lift up and
out.
7) Remove the burner by undoing the 2 screws shown.
a) Carefully slide the burner to the left.
b) Then lift the burner up and out carefully, ensuring not to spill
the glass crystals.
Door Frame
Glass Door
Burner
FAN REMOVAL