Regency U32S-LP5 Indoor Fireplace User Manual


 
12 U32S-5 FPI Direct Vent Gas Insert
INSTALLATION
WARNING!
Do not overtighten the screw.
Recommended to grip
the wrench by the short side.
13) Turn control knob to the “OFF” position.
14) Remove the black protection cap by
hand from the high-low knob (Fig.1).
15) Insert a 5/32” or 4mm Allen wrench into
the hexagonal key-way of the screw
(Fig. 2), rotate it counter-clockwise until
it is free and extract it.
16) Check that the screw is clean and if
necessary remove dirt.
17) Flip the screw (Fig. 3).
18) Using the Allen wrench as shown in
Fig.4, rotate the screw clockwise until
snug, do not overtighten.
19) Verify that if the conversion is from
NG to LPG, the screw must be re-
assembled with the red o-ring visible
(Fig. 5).
20) Re-assemble the black protection cap
(Fig. 6).
WARNING!
Also check that the pilot and
main burner injectors
are appropriate for the gas type.
Fig. 1
Fig.2
Fig.3
Fig.4
LPG Configuration
Red o-ring visible
Fig.5
Fig. 6
9) Pull off the pilot cap to expose the pilot
orifi ce.
10) Unscrew the pilot orifi ce with the
supplied allen key and replace it with the
LP pilot orifi ce and re-install the pilot cap
and the pilot shield.
11) Re-install base cover.
12) Re-install the burner.
NOTE: Before re-installing the burner,
ensure the LP areation setting is set
at 1/2" min. when using glass crystals
and 1/8" min. when using ceramic
stones.
21) See DC Sparker installation in the
instruction manual.
22) Attach the label "This unit has been
converted to LPG" near or on top of the
serial # decal.
23) Replace yellow "NG" label with red
"LPG" label.
24) Check for gas leaks.
25) Check inlet and outlet pressures.
26) Reverse Step 2.
27) Check operation of fl ame control.
Pilot Cap
Installer Notice:
These instructions must be left
with the appliance.