Regency U32-NG4 Indoor Fireplace User Manual


 
16 U32-4 FPI Direct Vent Gas Insert
28) Run the other end of the ground wire
and DC spark generator wires through
the bushing on the heat shield.
30) Plug the DC spark generator wires to the
DC Sparker.
31) Connect the ground wire to the DC Sparker
mounting bracket.
Heat Shield
34) Find a location which is not too hot and
is easy to reach for changing the battery.
Note: It should be kept away from the
chain.
35) Tie up the loose wires with the wire clip.
Chain
36) Check for gas leaks.
37) Check inlet and outlet pressures.
38) Check operation of fl ame control.
39) Check for proper fl ame appearance and
glow on logs.
NOTE: The battery in the DC Sparker
Box will need to be replaced an-
nually.
25) Connect the DC spark generator wires
to the SIT Valve with the screw, which is
provided in the kit.
26) Locate the ground lug.
27) Connect one end of the supplied green
ground wire to the lug with the nut and
washer from the kit.
Ground
wire from
kit
29) Install the 1/2" bushing to the heat
shield.
33) Mount the heat shield to the DC Sparker.
Secure into place with the velcro, which is
provided in the kit.
For P36D-1 / P36-4 Only:
26a) By the receptical box, left of the unit.
For U32-4 Only:
26b) Located on the left side of the unit.
32) Install the supplied battery into the DC
Sparker Box by opening the battery
compartment.
Battery
Compartment
INSTALLATION