Regency P48-NG2 Indoor Fireplace User Manual


 
8" dia.
Flue pipe
5” dia.
Flue pipe
Spring Spacer
AstroCap XL
(Part# 946-623/P)
WallThimble
Vinyl Siding
Standoff
Alternate Horizontal
Termination Caps
Snorkel Terminations
Snorkel Terminations:
For installations requiring a vertical rise on the exterior of the building, 14-
inch and 36-inch tall Snorkel Terminations are available. Follow the same
installation procedures as used for standard Horizontal Termination.
NEVER install the snorkel upside down.
Min. 12"*
(305mm)
Dura-Vent
Snorkel
Below Grade Snorkel Installation (Dura-Vent Only)
If the Snorkel Termination must be installed below grade, i.e. basement
application, proper drainage must be provided to prevent water from
entering the Snorkel Termination. Refer to Rigid Pipe Installation
instructions for details. Do not attempt to enclose the Snorkel within the
wall, or any other type of enclosure.
Min. 12"*
(305mm)
Adequate
drainage
Window
Well
Gravel
Dura-Vent
Snorkel
P48 Gas Fireplace
Regency Direct Vent System (Flex)
Horizontal Terminations Only
These venting systems, in combination with the P48 Direct Vent Gas
Fireplace, have been tested and listed as a direct vent heater system
by Warnock Hersey. The location of the termination cap must conform
to the requirements in the Vent Terminal Locations diagram.
FPI Direct Vent (Flex) System Termination Kits include all the parts
needed to install the P48 using a fl exible vent.
FPI Kit # Length Contains:
#946-618 6 Feet 1) 6-5/8” fl exible liner (Kit length)
2) 4” fl exible liner (Kit length)
3) spring spacers (3)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) S.S. screws #8 x 1-1/2” drill point, (4)
10) vinyl siding standoff
#946-616 10 Feet
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex
installations.
3) Horizontal sections must be supported every 3 feet.
If required by the external termination location the listed
alternate termination caps may be used. (Refer to Page 11)
Alternate Snorkel
Termination Cap
Part #1282 (14”)
Part #1281 (36”)
63June 2007 Regency Product Specifi cations Book