Regency P48-1 Indoor Fireplace User Manual


 
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 17
INSTALLATION
Vertical Venting with Three (3) 90
o
Elbows
Option V H + H1 V + V1
A) 2' Min. 3' Max. 4' Min.
B) 3' Min. 4' Max. 6' Min.
C) 4' Min. 5' Max. 7' Min.
D) 5' Min. 6' Max. 8' Min.
E) 6' Min. 7' Max. 9' Min.
F) 7' Min. 8' Max. 10' Min.
With these options, max. to-
tal pipe length is 30 feet with
min. of 10 feet total vertical
and max. 8 feet total horizon-
tal.
Please note min. 1 foot
between 90
o
elbows is re-
quired.
Vertical Venting with Three (3) 90
o
Elbows
Option H V H + H1 V + V1
A) 1' Max. 1' Min. 3' Max. 3' Min.
B) 2' Max. 2' Min. 4' Max. 5' Min.
C) 3' Max. 3' Min.' 5' Max. 7' Min.
D) 4' Max. 4' Min. 6' Max. 9' Min.
E) 5' Max. 5' Min. 7' Max. 11' Min.
With these options, max. total
pipe length is 30 feet with min.
of 11 feet total vertical and
max. 7 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is re-
quired.
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.