MAINTENANCE
WARNING
The use of substitute glass will
void all product warranties.
Do not operate the appliance
with the glass panel(s) removed,
cracked or broken. Replacement of
the glass panel(s) should be done
by an authorized service person.
GLASS
REPLACEMENT
Your P42 fireplace is supplied with high
temperature, 5 mm Neoceram ceramic glass
that will withstand the highest heat that your
unit will produce. In the event that you break the
glass, purchase your replacement glass from an
authorized Regency
®
dealer only, and follow the
step-by-step instructions for glass, glass gasket
and door gasket replacement.
DOOR GLASS
Your Regency
®
fi replace is supplied with high
temperature, 5 mm Neoceram ceramic glass that
will withstand the highest heat that your unit will
produce. If your glass requires cleaning, we
recommend using an approved glass cleaner
available at all authorized dealers. Do not use
abrasive materials. Do not clean the glass
when hot.
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency
®
dealer only, and follow our step-by-
step instructions for replacement.
GOLD-PLATED
LOUVERS
The 24 carat gold-plated fi nish on the louvers
and trim requires little maintenance, and need
only be cleaned with a damp cloth.
DO NOT use abrasive materials or chemical
cleaners, as they may harm the fi nish and void
the warranty.
Clean any fi ngerprints off before turning
the unit on.
LOG REPLACEMENT
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door and carefully remove the
logs. (The pilot light generates enough heat to
burn someone.) If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagrams under Log
Installation.
Note: Improper positioning of logs may
create carbon build-up and will
severely alter the unit's performance
which is not covered under
warranty.
THERMOPILE /
THERMOCOUPLE
1) Remove the top louver and open the bottom
louvers.
2) Open and remove door.
3) Remove front logs.
4) Remove burner.
5) Loosen the thermocouple or thermopile with
a 7/16" wrench.
6) Disconnect thermocouple by loosening
nut from the valve with a 9mm wrench.
Disconnect thermopile by loosening 2
screws marked TP on the valve.
7) Peel the silicone from the hole in the base
of the unit and drop the thermocouple or
thermopile down from the bracket and pull
it out of the unit.
8) Reinstall the new ones in reverse order
making sure to seal the hole in the fi rebox
with silicone in order to maintain the seal
integrity of the fi rebox.
Flush Glass Replacement
Remove the fl ush door front (as per instructions in
the "Standard Flush Door" section). Remove the
4 glass clips from each corner. Slide in the new
replacement
glass. Push the
4 glass clips
back onto the
frame.
The glass must
have gasketing
around it.
Caution: Wear gloves when removing
damaged or broken glass.
Bay Glass Replacement
1) Remove the door from the unit and place
on a soft surface to prevent scratching.
2) Remove the nuts holding the glass clips in
place and remove.
3) Replace the glass. The glass must have
gasketing around it.
4) Reverse the previous steps, replace the
glass clips and fasten with the nuts but do not
over tighten, as this can break the glass.
5) Replace door on the fi replace and check
the seal.
WARNING: Do not operate the
appliance with the glass panels
removed, cracked or broken.
Replacement of the glass panels
should be done by a licensed or