MAINTENANCE
MAINTENANCE
6 ) Remove the top screw and loosen the
bottom screw that hold the power module
in place.
7) Remove the power module cover by
removing the 2 screws, one on each side.
8) Remove the 3 connectors from the circuit
board.
9) Remove the circuit board from the support
bracket by turning it around and pushing
the plastic pins with a plier.
1) Remove the exterior brick panels.
2) Remove the glass door.
4) Lift up and pull out the heat shield slightly
to clear the screwheads and then hang it
on the top bracket (located directly above
the heat shield).
3) Loosen the 2 screws that hold the left side
heat shield in place.
Power
Module
Power Module with Cover Removed
Circuit Board Removed
POWER MODULE REPLACEMENT
10) Replace the circuit board.
11) Reverse steps to re-install.
5) Unplug the power source.
Heat
Shield
Bracket
Heat
Shield
a. Release the 2 door latches on the left
and right side at the top of the fi rebox.
b. Swing the door out from the top and release
the hinges on the left and right side of the
door by lifting them up.
Hinge
Door
Latch
Latch Location
Power Module