Regency L900-NG Indoor Fireplace User Manual


 
Regency
®
L900 Direct Vent Gas Fireplace 31
INSTALLATION
LP Conversion Kit Contains:
Qty. Part # Description
1 910-462 LP Conversion Coil
1 904-573 Cable Tie
1 910-037 LP Pilot Orifi ce
1 904-641 Orifi ce #50 (back)
1 904-241 Orifi ce #56 (front)
1 904-529 Allen Key
1 918-590 LP Conversion Decal
1 908-528 Red Propane Label
1 918-608 Instruction Sheet
1) Turn control knob to the OFF position and
shut off the gas supply to the valve.
2) Remove exterior brick panels, if installed.
3) Remove the glass door.
a. Release the 2 door latches on the left
and right side at the top of the fi rebox.
b. Swing the door out from the top and
release the hinges on the left and right
side of the door by lifting them up.
Latch
c. Place the door on a soft surface to prevent
scratching.
Hinge
Door
Latch Location
Heat
Shield
4) Loosen the 2 screws that hold the left side
heat shield in place.
5) Lift up and pull out the heat shield slightly
to clear the screwheads and then hang it
on the top bracket (located directly above
the heat shield).
Bracket
Heat
Shield
6) Unplug the power source.
7) Remove the log set, if installed.
8) Remove interior brick panels, if installed.
9) Remove the grate by undoing the 2 screws
on the right and left side.
10) Remove the front burner by removing the
screw.
11) Remove the back burner by removing the
screw.
12) Remove the rear log stand by removing
the 4 screws.
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER, IF IN DOUBT DO NOT DO THIS CONVERSION!!
LP Conversion instructions for when unit is ALREADY INSTALLED.
Grate
Front Burner
Front Burner Removed
Back Burner
Rear Log Stand
INSTALLATION