Regency Freestanding Woodstove
13
RECOMMENDED HEIGHTS FOR
WOODSTOVE FLUE
Simple rules on draft. See Table 1.
1) At sea level minimum height is 12' (3.7m)
straight.
2) Add the following vertical height to compen-
sate for:
45 deg. elbow = 1 ft. (.3m)
90 deg. elbow = 2 ft. (.6m)
"T" = 3 ft. (.9m)
Each foot of horizontal run = 2 ft. (.6m)
3) Add 4% overall for each 1000' (3.5m) above
sea level.
Example: a)
1-1/2 ft. of horizontal run = 3 ft. (.9m)
one "T" = 3 ft. (.9m)
Total Addition (at sea level) = 6 ft. (1.8m)
Example: b)
One 90 deg. elbow = 2 ft. (.6m)
2 ft. of horizontal run = 4 ft. (1.2m)
one "T" = 3 ft. (.9m)
Total Addition (at sea level) = 9 ft. (2.7m)
Recommended Flue Height
Elevation Example a) Example b)
0' (0m) 18' (5.5m) 21' (6.4m)
1000' (305m) 18.72' (5.7m) 21.84' (6.7m)
2000' (610m) 19.44' (5.9m) 22.68' (6.9m)
5000' (1524m) 21.60' (6.6m) 25.20' (7.7m)
8000' (2438m) 23.76' (7.2m) 27.72' (8.5m)
TABLE 1
MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET
(Measured from the top of the unit)
# OF ELBOWS
ELEVATION (FT)
ABOVE SEA LEVEL 0 2 x 15
o
4 x 15
o
2 x 30
o
4 x 30
o
2 x 45
o
4 x 45
o
0-1000 12.0 13.0 14.0 15.0 18.0 16.0 20.0
1000-2000 12.5 13.5 14.5 15.5 19.0 16.5 21.0
2000-3000 13.0 14.0 15.0 16.0 19.5 17.0 21.5
3000-4000 13.5 14.5 15.5 17.0 20.0 18.0 22.5
4000-5000 14.0 15.0 16.0 17.5 21.0 18.5 23.0
5000-6000 14.5 15.5 17.0 18.0 21.5 19.0 24.0
6000-7000 15.0 16.0 17.5 18.5 22.5 20.0 25.0
7000-8000 15.5 16.5 18.0 19.0 23.0 20.5 25.5
8000-9000 16.0 17.0 18.5 20.0 24.0 21.0 26.5
9000-10000 16.5 17.5 19.0 20.5 24.5 22.0 27.0
NOTE: No more than two offsets (four elbows) allowed. Two 45
o
elbows equal one 90
o
elbow.