Regency CS1200 Freestanding Wood Stove
INSTALLATION
Z
6"
6"
16"
Y
Y
X
X
6"
for angled corners
6"
16"
6"
6"
Z
The Regency Freestanding models have been alcove approved and must be installed
with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 84"
Maximum depth of alcove - 36"
Minimum Overall Width (X) of Floor
Protector for all installations:
US 38-3/4"
Canada 42-3/4"
Floor Protection
A combustible fl oor must be protected by a non-combustible material (like tile,
concrete board, or certifi ed to UL-1618 or as defi ned by local codes) extend-
ing beneath the heater and a minimum of 6" from each side and minimum
16" from the front face of the stove and minimum 6" (or the rear clearance to
combustibles whichever is smaller) from the rear of the stove.
NOTE: In Canada, fl oor protection must extend 18" to the front and 8" to each side of the stove.
Minimum Alcove Clearance to Combustible Materials
Unit From Back Shield
+ Side Shields.
From Flue
Center-Line
Min.
Width
Min. Hearth
to Rear Wall
CS1200
GH I J KL
11" 7" 24-1/2" 14-1/2" 49-1/8" 39-1/4"
Minimum Overall Depth (Y) of Floor Protector
Unit Residential
"C" Vent
Residential
Close Clearance
Mobile Home
Close Clearance
Alcove
CS1200
YZ
Y
Z
Y
Z
YZ
USA
39" 6" 39 6" 39" 6" 39" 6"
Canada
43" 8" 43" 8" 43" 8" 43" 8"
MINIMUM ALCOVE CLEARANCE TO COMBUSTIBLE MATERIALS
MEASUREMENTS "FROM UNIT" ARE FROM THE SIDE SHIELDS OF THE STOVE TO A SIDE WALL OR TO A CORNER, AND
FROM THE REAR HEAT SHIELD TO A BACK WALL