3
1. RECEIVING EQUIPMENT
On receipt of your equipment it is suggested that you
visually check for external damage to the carton. If the
carton is damaged, it is suggested that a note be made
on the Bill of Lading when signing for equipment. Remove
the heater from the carton and if it is damaged report the
damage to the carrier immediately. Be sure that you
receive the number of packages indicated on the Bill of
Lading. Claims for shortages and damages must be
filed with carrier by consignee.
Purchased parts are subject to replacement only
under the manufacturer's warranty. Debits for defective
replacement parts will not be accepted and defective
parts will be replaced in kind only per our standard
warranties.
When ordering parts, you must specify Model and
Serial Number of the heater. When ordering under
warranty conditions, you must also specify date of
installation.
Raypak recommends that this manual be re-
viewed thoroughly before installing your Raypak
Heater. If there are any questions which this manual
does not answer, please contact your local Raypak
representative.
2. GENERAL SPECIFICATIONS
The Raypak water heaters are design certified by the
American Gas Association, and tested under the require-
ments of the American National Standard, ANSI
Z21.10.3. Each heater has been constructed and
pressure tested in accordance with the requirements of
Section IV of the American Society of Mechanical Engi-
neers Code, and factory fire tested.
The heaters are designed for indoor installation with
a built-in drafthood, and a built-in sub-base for combus-
tible flooring. Models are available with standing pilot,
or with intermittent ignition device (I.I.D). The heaters are
equipped with the following components: water circula-
tion pump, pressure relief valve, manual reset high limit
switch, fast response temperature sensor, 40 VA trans-
former, vent thermal switch, flame roll-out switch, and
redundant combination gas valve. A tankstat is supplied
loose for installation in the field.
INPUT
MBH
90
135
195
MODEL
WH-0090
WH-0135
WH-0195
RECOVERY
GPH
90
132
192
TANK
GAL.*
80
80
80
PIPING
CONNECTIONS
WATER GAS
NPT. NPT.
1" 1/2"
1-1/4" 1/2"
1-1/4" 1/2"
K
VENT
DIA.
5"
6"
7"
B
5-3/4
6-1/4
6-1/4
A
11"
18"
18"
Fig. #8978.5.1
*May be used with other tank size capacity.
Note: Recovery GPH based on Manufacturer's rating.
SPECIFICATIONS AND DIMENSIONS