QLAC / LS (LOW NOISE VERSION)
COOLING CAPACITIES AND COMPRESSOR INPUT POWER
PF (kW) PA (kW)
TA (°C) TA (°C)
MOD. TU (°C)
20 25 30 35 40 45 20 25 30 35 40 45
-5 26,64 24,98 23,36 21,79 --- --- 9,39 10,50 11,71 13,02 --- ---
-3 29,27 27,48 25,74 24,04 --- --- 9,36 10,50 11,76 13,13 --- ---
-1 32,07 30,15 28,28 26,44 --- --- 9,32 10,48 11,77 13,21 --- ---
1 35,05 33,00 30,98 29,00 --- --- 9,28 10,44 11,77 13,25 --- ---
3 38,23 36,02 33,85 31,73 29,65 --- 9,24 10,41 11,75 13,27 14,94 ---
5 41,60 39,24 36,91 34,63 32,39 --- 9,21 10,36 11,72 13,26 14,98 ---
7 45,18 42,66 40,17 37,71 35,31 32,95 9,19 10,33 11,68 13,24 15,00 16,93
9 48,97 46,28 43,62 40,99 38,41 35,87 9,19 10,30 11,64 13,21 14,99 16,97
11 52,99 50,12 47,28 44,48 41,71 38,98 9,21 10,28 11,60 13,17 14,97 16,98
13 57,24 54,19 51,16 48,17 45,21 42,29 9,26 10,28 11,57 13,13 14,93 16,97
040
15 61,74 58,50 55,27 52,08 48,92 45,80 9,34 10,30 11,56 13,09 14,90 16,95
-5 33,41 31,45 29,48 27,48 --- --- 11,23 12,52 13,96 15,56 --- ---
-3 36,45 34,36 32,24 30,11 --- --- 11,22 12,53 13,99 15,60 --- ---
-1 39,69 37,45 35,19 32,90 --- --- 11,21 12,53 14,01 15,64 --- ---
1 43,13 40,75 38,33 35,89 --- --- 11,19 12,53 14,02 15,67 --- ---
3 46,80 44,25 41,67 39,06 36,42 --- 11,18 12,52 14,02 15,69 17,54 ---
5 50,69 47,98 45,23 42,44 39,63 --- 11,16 12,51 14,03 15,71 17,58 ---
7 54,83 51,94 49,01 46,00 43,04 40,00 11,14 12,50 14,02 15,72 17,61 19,70
9 59,21 56,14 53,02 49,86 46,66 43,43 11,12 12,48 14,02 15,73 17,63 19,74
11 63,85 60,59 57,27 53,91 50,51 47,07 11,09 12,47 14,01 15,73 17,65 19,78
13 68,77 65,30 61,78 58,21 54,60 50,95 11,07 12,45 14,00 15,73 17,66 19,80
045
15 73,96 70,28 66,55 62,77 58,94 55,06 11,05 12,43 13,98 15,73 17,67 19,83
-5 39,58 37,29 34,94 32,53 --- --- 12,52 13,96 15,50 17,15 --- ---
-3 43,08 40,64 38,14 35,57 --- --- 12,50 13,98 15,58 17,30 --- ---
-1 46,80 44,21 41,54 38,82 --- --- 12,47 13,98 15,63 17,41 --- ---
1 50,76 48,00 45,17 42,27 --- --- 12,43 13,97 15,66 17,49 --- ---
3 54,98 52,04 49,03 45,95 42,79 --- 12,38 13,94 15,66 17,54 19,58 ---
5 59,45 56,33 53,13 49,86 46,50 --- 12,34 13,90 15,64 17,57 19,66 ---
7 64,19 60,88 57,49 54,00 50,46 46,82 12,29 13,85 15,62 17,57 19,71 22,03
9 69,22 65,71 62,12 58,43 54,66 50,80 12,25 13,81 15,58 17,56 19,74 22,11
11 74,55 70,83 67,02 63,11 59,12 55,04 12,22 13,77 15,54 17,53 19,74 22,17
13 80,19 76,25 72,21 68,08 63,85 59,53 12,21 13,73 15,50 17,50 19,74 22,20
050
15 86,14 81,97 77,70 73,34 68,87 64,31 12,22 13,70 15,46 17,46 19,71 22,21
-5 44,18 41,55 38,86 36,12 --- --- 14,46 16,14 17,97 19,95 --- ---
-3 48,09 45,29 42,42 39,49 --- --- 14,47 16,18 18,07 20,12 --- ---
-1 52,26 49,27 46,22 43,09 --- --- 14,46 16,20 18,13 20,25 --- ---
1 56,69 53,51 50,26 46,93 --- --- 14,45 16,21 18,18 20,35 --- ---
3 61,41 58,02 54,56 51,02 47,40 --- 14,43 16,21 18,21 20,42 22,85 ---
5 66,42 62,82 59,14 55,37 51,52 --- 14,42 16,20 18,22 20,47 22,95 ---
7 71,73 67,91 64,00 60,00 55,91 51,74 14,40 16,18 18,21 20,49 23,02 25,78
9 77,37 73,31 69,16 64,91 60,58 56,15 14,40 16,17 18,21 20,51 23,07 25,88
11 83,34 79,04 74,63 70,13 65,54 60,85 14,41 16,16 18,20 20,51 23,10 25,96
13 89,66 85,10 80,43 75,67 70,80 65,84 14,44 16,17 18,19 20,50 23,11 26,01
060
15 96,34 91,51 86,57 81,53 76,39 71,14 14,50 16,19 18,19 20,50 23,12 26,04
TU: Outlet water temperature (°C)
TA: Ambient temperature (°C)
PA: Compressors input power (kW)
PF: Cooling capacity (kW)