12 Quadra-Fire • Fogata Grande
E. High Altitude Installations
OMNIgasappliancesaretestedandapprovedwithoutre-
quiringchangesforelevationsfrom0to2000ftintheUSA
andCanada.
Wheninstallingthisapplianceatanelevationabove2000ft,
itmaybenecessarytodecreasetheinputratingbychang-
ingtheexistingburneroricetoasmallersize.Inputrate
shouldbereducedby4%foreach1000ftabovea2000ft
elevationintheU.S.A.,or10%forelevationsbetween2000
and4500ftinCanada.Iftheheatingvalueofthegashas
beenreduced,theserulesdonotapply.Toidentifytheprop-
eroricesize,checkwiththelocalgasutility.
Ifinstallingthisapplianceatanelevationabove4500ft(in
Canada),checkwithlocalauthorities.