Quadra-Fire CB1200-B Stove User Manual


 
Page 2
7014-082D
September 1, 2008
R
CB 1200 Pellet Stove
R
R
Correct Flame Size, Yellow/White in Color
Correct
Figure 32.3
Ash Build Up in Firebox
Pellets Back Up
In Feed Tube
Firepot Overfills
Tall, Lazy Flame, Orange in Color
Incorrect
Figure 32.1
Figure 32.2
D. High Ash Fuel Content Maintenance
Frequency: When the ash build-up exceeds more
than half way up the repot.
By: Homeowner
1. Convection Blower Replacement
a. Use proper shut down procedures to shut down the
appliance and let it completely cool.
b. The convection blower is located at the bottom rear
of the appliance. If an outside air kit is also installed,
depending on your particular installation you may or
may not have to remove the outside air ange. If you
do, remove the 2 screws using a Phillips head screw-
driver. You do not need to remove the ex pipe from
the ange.
c. Remove the lower rear screen by removing the 4
screws securing the screen to the unit.
d. The motor is mounted on a removable bracket. Remove the
2 screws just above the motor and the whole assembly will tilt
down and pull out.
e.
Disconnect the wires from the blower. The wires coming
from the wiring harness are white, red and tan and the
wires coming from the blower are black, white and red.
The white connects to white, the red to red and black to
the tan color wire.
E. Blower Replacement
Figure 32.4
Remove 2 Screws
Remove 4 Screws
Outside Air
Flex Hose
Convection Blower
Poor quality pellet fuel, or lack of maintenance, can create
conditions that make the repot ll quickly with ashes and
clinkers.
This condition makes the appliance susceptible to overll-
ing the repot with pellets which may result in smoking,
sooting and possible hopper res. Figure 32.1 shows an
example where the repot overlls, pellets back up into the
feed tube and ash has accumulated in the rebox.
An inefcient and non-economical method of burning of
fuel caused by poor quality pellet fuel is shown in Figure
32.2.
The correct ame size when good quality, premium pellet
fuel is burned is shown in Figure 32.3.
If the ash buildup exceeds the half way point in the repot
IMMEDIATE ATTENTION AND CLEANING IS REQUIRED.