3100 Wood Stove Series (ACC)
A. Hearth Protection Requirements
FLOOR PROTECTION: Floor protector must be non-com-
bustible material, extending beneath heater and to the front,
sides and rear as indicated. The fl oor must be non-com-
bustible or otherwise adequately protected from radiant heat
given off by the unit and from sparks and falling embers. A
layer of thin brick or ceramic tile over a combustible fl oor is
not suffi cient.
For the Millennium Model In US installations, i
t is nec-
essary to install a fl oor protector of a minimum of 3/8 inch
(9.5mm) thick metal clad millboard or equivalent a minimum
of 16
inches (406mm) in front of glass and 8 inches (203mm)
to both sides of the fuel loading door. Open the door and
measure 8 inches (203mm) from the side edge of the open-
ing in the face of the appliance. *See exception.
16" from glass
8 in.
USA
Fuel loading door
4-7/8 in.
3-1/8 in."
31-5/8 in.
minimum
39-5/8 in.
minimum
Must extend 2 in. (51mm) beyond
each side of pipe (shaded area)
CANADA
203mm (8 in.)
203mm
(8 in.)
203mm
(8 in.)
457mm (18 in.)
1260mm
(49-5/8 in.)
minimum
1041mm (41 in.)
minimum
In Canada, similar fl oor protection must be provided 18
inches (457mm) in front and 8 inches (203mm) from the
sides and rear of the stove. *See exception.
*EXCEPTION: Non-combustible fl oor protections must
extend beneath the fl ue pipe when installed with horizontal
venting and extend 2 inches (51mm) beyond each side.
See Figure 12.4.
USA required
Canada recommended
Figure 12.3
4
Installation
Figure 12.1
Figure 12.2
Figure 12.4
WARNING
Fire Risk.
• Hearth pads must be installed exactly as
specified.
High temperatures or hot embers may ignite
concealed combustibles.
Millennium Model
o
p
t
i
o
n
a
l
co
ve
r
a
g
e
o
p
t
i
o
n
a
l
co
ve
r
a
g
e
1
5
-
7
/
8
i
n
.
49-7/8 in.
o
p
t
i
o
n
a
l
co
ve
r
a
g
e
3
9
-
5
/
8
i
n
.
1
6
i
n
.
3
1
-
5
/
8
i
n
.
27-5/8 in.
27-5/8 in.
11
-
3
/
8
i
n
.
r
e
q
u
i
r
e
d
co
ve
r
a
g
e
49-7/8 in.
USA