Quadra-Fire 3100 Stove User Manual


 
INSTALLATION OF OPTIONAL BLOWER
Part #831-1700
The blower is shipped fully assembled and ready for installation.
1. Remove three ¼”-20 (3/8” hex head) bolts from blower cover, and remove nutbar. Discard nutbar.
2. Using bolts, attach blower to lower rear of stove, as shown.
3. Plug blower cord into a grounded outlet. Do not remove ground prong from plug. Route power cord to
avoid heat from the stove, or other damage.
4. Adjust the blower speed control to the desired speed.
BLOWER SWITCH ADJUSTMENTS
The blower speed control for this unit is adjusted at the factory, and should not require further adjustment.
When the speed control is turned clockwise, it will click on to high speed. Turn the speed control clockwise to
decrease the speed. At full clockwise, the blower should blow gently, but should not stop.
STEPS FOR ADJUSTING THE BLOWER SPEED CONTROL
1. With the unit plugged in, turn the speed control knob to slow (full clockwise).
2. With a small screwdriver, adjust the blower speed by turning the adjustment mechanism through the hole
on the side of the speed control.
3. Adjust the speed so the blower runs slowly, but does not stop. Turn clockwise to slow the blower and
counterclockwise to increase the speed.
Page 27
BLOWER SPEED CONTROL