Procom EN250RYLB-O Indoor Fireplace User Manual


 
15
SPECIFICATIONS
Btu 20,000/25,000 20,000/ 25,000
Gas Type LP Gas Natural Gas
Ignition Automatic Automatic
Manifold Pressure 8"W.C. 3"W.C.
Inlet Gas Pressure
(In. of water)*
Maximum 14" 10.5"
Minimum 11" 5"
Dimensions, Inches (H
×
W
×
D)
Stove 38 3/16”
×
26 3/8”
×
14 1/8”
Carton 40 1/8”
×
29 5/16”
×
15 5/16”
Weight, lbs
Stove 78
Shipping 94
voltage 120 120
watt 27 27
*For purposes of input adjustment
EL250RYLB-O
EN250RYLB-O
Delayed ignition burner
1. Manifold pressure is too low
2. Burner orifice clogged
1. Contact local gas company
2. Clean burner (see Cleaning and
Maintenance, page 12)
Burner backfiring during combustion
1. Damaged burner
2. Gas regulator defective
1. Clean burner orifice (see Cleaning
and Maintenance, page 12)
2. Replace gas regulator
Slight smoke or odor during initial
operation
1. Residues from manufacturing
processes
2. Not enough air
3. Gas regulator defective
1. Problem will stop after a few hours
of operation
2. Check burner for dirt and debris.
If found, clean burner (see Cleaning
and Maintenance, page 12)
3. Replace gas regulator
Dark residue on logs or inside of
fireplace
1. Improper log placement
2. Air holes at burner inlet blocked
3. Burner flame holes blocked
1. Properly locate logs (see installing
logs, page 21)
2. Clean out air holes at burner inlet.
Periodically repeat as needed.
3. Remove blockage or replace burner
Heater produces a clicking/ticking
noise just after burner is lit or shut off
1. Metal expanding while heating
or contracting while cooling
1. This is common with most heaters. If
noise is excessive, contact qualified
service person
TROUBLESHOOTING
Continued