INSTALLATION OF FAN COIL:
The extended liquid and suction pipes and drain hose are hidden inside a slot at the
back of the fan coil. This allows the hole on the wall to be either on the right or left side
of the fan coil.
RIGHT SIDE HOLE POSITION: The piping and drain hose are routed straight through
the hole.
LEFT SIDE HOLE POSITION: The
piping and drain hose run from the
right side to the left side of the unit,
hidden in the slot at the back of the
unit before routing through the hole
on the left side of the unit.
MOUNTING FAN COIL UNIT:
Hook the fan coil onto the upper
portion of the installation plate
ensuring that it sits securely on the
installation plate.
Press the lower portion of the unit
against the installation plate until the
hooks at the back of the unit are
securely engaged with the installation
plate.
MOUNTING CONDENSING UNIT:
Do not place the condensing unit
directly on the ground. It should
preferably be placed on a slightly
raised platform to prevent rain water
from splashing into it. Also ensure
that it is level. Avoid installing the unit
in places where flammable gases
may be present.
If necessary, due to the placement conditions,
rubber cushions can be placed underneath the
outdoor unit.
beams or blocks