Pentair JSAYDL Water Pump User Manual


 
10
Draining Pump:
To avoid dangerous or fatal electrical shock hazard, turn OFF power to
motor before draining pump.
NOTICE: Do not use anti-freeze solutions (except propylene glycol) in
your spa system. Most anti-freezes are hightly toxic and may damage
plastic components in the system. Propylene glycol is non-toxic and will
not damage pump components.
1. Close all valves on suction and return piping.
2. Remove drain plug in bottom of front plate.
3. Drain all piping and storage tanks exposed to freezing temperatures.
4. Be sure no airlocks are holding water in system.
5. Consult spa and filter owner’s manuals for instructions about draining the
rest of the system.
NOTICE: We recommend a drain plug or valve at the low point of the spa
piping to help drain spa system.
6. Before restarting, replace all plugs and make sure all pipe connections
are tightly sealed.
Startup for Winterized Equipment:
1. Remove any temporary weather protection placed around system for
shutdown.
2. Follow filter manufacturer’s instructions for reactivation of the filter.
3. Inspect all electrical wiring for damage or deterioration over the shutdown
period. Have a qualified serviceman repair/replace wiring as needed.
Inspect and tighten all watertight connections.
4. Open all valves in suction and return piping.
5. Remove all winterizing plugs in spa system.
6. Remove all anti-freeze solutions from system.
7. Close all drain valves and replace all drain plugs in spa system.
8. Fill spa with water to proper level (see spa manufacturer’s instructions).
Hazardous voltage.
Can shock, burn,
or cause death.
Disconnect power
before working
on pump or motor.