ADDITIONAL FEATURES
This heater has additional features:
Dual LED display-Allows you to adjust the heater and check the set value at the
same time in a distance (Within16 ft of the heater), you can also check the status of
the heater easier.
Convenient Carry Handle-Allows for easy maneuvering from room to room.
TROUBLESHOOTING
If your heater fails to operate, please follow these instructions:
Ensure that your circuit breaker or fuse is working properly.
Be sure the heater is plugged in and that the electrical outlet is working properly.
Check for any obstruction. If you find any obstruction, turn the heater “OFF”. Unplug
the heater and wait a few minutes for it to cool down. Carefully remove the
obstruction. Plug the heater in and turn it on again by referring to the OPERATING
INSTRUCTIONS.
NOTE: IF YOU EXPERIENCE A PROBLEM WITH YOUR HEATER, PLEASE SEND
YOUR HEATER TO AN AUTHORISED SERVICE CENTER FOR MAINTENCE.
PLEASE DO NOT ATTEMPT TO OPEN OR REPAIR THE HEATER YOURSELF.
DOING SO MAY VOID THE WARRANTY AND COULD CAUSE DAMAGE OR
PERSONAL INJURY.
CLEANING AND STORAGE
It is recommended that the heater be cleaned at least one time during the operating season in
order to provide the optimum level of performance. ALWAYS TURN THE POWER SWITCH
OFF AND UNPLUG THE HEATER BEFORE CLEANING. Be sure to save the box for off-
season storage.
Turn the heater “ OFF” , unplug it and wait for the heater to cool down.
Use a dry cloth to clean only external surfaces of the heater.
Do not use any cleaning agents or detergents.
Never immerse the heater in water.
Pack the heater in the original carton and store it in a cool and dry place.
SPECIFICATIONS
Model No.: HC-0119A
Voltage: 120V, 60Hz
Current: Maximum continuous draw: 12.5 Amps.
Power: LO = 900 Watts, HI = 1500 Watts.
Tolerances on all specifications: Approximately +5%, -10%.
B.
If the setting temperature is lower than or equal to the room temperature, the
temperature display will flash and the unit will stop heating. When the room
temperature falls down to less than the setting temperature, the unit will
resume heating. The heater will cycle on and off this way to maintain the
setting temperature.
Note: Every time you turn on the heater, the heater will heat forcedly for 2 minutes. After that the
heater will work based on the below instruction. And when the room temperature reaches the
setting temperature or the setting temperature is lower or equal to the room temperature, the
heating element will shut off immediately, but the fan motor will continue running for 10—30
seconds before shutting off. This is a safety feature to protect the unit from being too hot.
Timer setting: This heater has an 8 hours On/Off timer. You can set an “ On” timer
when the heater is standing by (plugged in but not working) or you can set an “ Off”
timer when the heater is working. For example, you can plug in the heater and set the
timer to turn the heater on after 3 hours, you can also set the timer to turn the heater
off after 6 hours and a half when the heater is working.
Example for “ On” Timer:
1. When the heater is plugged in and not working, press the “ C” Timer and the “ A” Digital
Indicator will display the last set value (0.0 is the default set). Press the “ Up” or “ Down”
key to choose your desired timer setting. The timer will increase or decrease half on hour
every time you press the “ Up” or “ Down” key and goes up and down from 0.0 to 8.0.
2. Press “ Up” key 6 times until 3.0 is displayed, press the “ C” Timer again to confirm the set.
Now your heater is set to be turned on after 3 hours.
Example for “ Off” Timer:
1. When the heater is working, press the “ C” Timer.
2. Press “ Up” key 13 times or “ Down” key 3 times until 6.5 is displayed, press the “ C” Timer
again to confirm the set.
Now your heater is set to be turned off after 6 hours and a half.
To disable the timer, adjust the set value of the timer to 0.0.
Note: Once the timer is set, the heater will work this way unless you unplug the heater. You have
to reset the timer every time you plug in your heater.
Remote control (Refer to Fig 2): This heater has a 6 key remote with the
following function (See picture above):
1. ON/OFF: Power switch key, used to turn off the heater when the heater is on.
2. OSC: Oscillation switch, used to enable the oscillation function by pressing once. To
disable the oscillation function, press the “OSC” key once more. This key is only valid
when the heater is on (Hi, Low or Fan).
3. TIMER: Timer setting key, used to enable the timer setting or confirm the setting value.
4. MODE: Mode select key, used to switch the heater circularly in sequence of HI -LO -
FAN when the heater is on.
5. “ +” and “ -” : Value adjustment key, used to adjust the set value of the temperature or
the timer.
CAUTION: This heater includes an Overheat Protection System that shuts the unit off if it
overheats due to abnormal conditions. If this occurs turn the heater “OFF”, unplug it, and inspect
and remove any objects on or adjacent to the heater. Allow it to cool for a few minutes, plug it
back in, and resume normal operation.